CONFIGURATION OF THE OPERATION "JUMPER" AND FAULT RESET
" T " → Close = 55 seconds shot | Open = shot managed by the alarm control panel (55" max.)
" I " → Close = input and output in N.O. mode| Open = input e output in N.C. mode
" L " → Opened for 3 seconds = Liquid Level Reset (Restore to 385" of autonomy)
" L " → Close = level control activated | Steadily Open = liquid level count is excluded
" Reset " → (Jumper located in the center of the electronic board) Opened for 3 sec. = Fault Reset
BURNER MANAGEMENT
The burner is activated only when the machine is ARMED, this can only happen by activating
the "ARM" input:
• ARMING the appliance (ARM), the heating resistance will be activated ("HEAT" light on)
• The heating switches off only after reaching 100% of the operating temperature (the
"HEAT" light will flash).
• When the temperature drops below the preset threshold, it will reactivate for a few
seconds.
See
SHOT MANAGEMENT
The shot is inhibited when:
- the device is DISARMED
- it is in the "forced pause cycle" state (5 minutes) after a shot
- the burner temperature is lower than that necessary to deliver quality dry fog.
Fog delivery can be interrupted by DISARMING the device or if the "T" Jumper is open,
interrupting the signal on the FOG terminal.
BACKUP BATTERY MANAGEMENT
The backup battery must be connected before the device is put into operation.
His health or presence is measured every 10 hours.
If the charge level is low (showing poor performance) the "BATT" LED will flash once per
second. On the other hand, if the battery is completely discharged or absent, the "BATT"
LED will put out a sequence of 3 flashes followed by a pause.
In both cases the "BAT" and "FAULT" outputs will be activated.
Once the battery has been replaced to reset the fault, the device must be restarted by
disconnecting it or by temporarily removing the fuse.