Start-up and testing
It is possible to test the machine independently of a connection to an alarm control panel
by acting directly on the COM, ARM and FOG terminals.
It is possible to test the system by using water instead of the fog liquid, in this way a dry
and transparent but "noisy" steam will be shooted, thus it is possible to test the interface
without unnecessarily saturating the room with fog.
with the alarm control panel,
Tank Installation
STARTUP
• Connect the 12V battery (the Power200, if installed)
• If Power200 is not installed, supply the "IN-12+" terminal with 12V from the control panel
• Activate the 230V power supply
• Arm the appliance by using "ARM", when it is ready, the "HEAT" light will flash
• Activate the shot by using "FOG"
To stop the "shot" cycle, it is necessary to disarm the appliance by opening the ARM
contact or releasing FOG.