6.2 Securing to the floor
To secure the product to the floor, fasten the supplied brackets
as shown in fig. 10.
fig. 10- Fastening brackets
Then secure the unit to the floor with the aid of suitable plugs,
not supplied, as shown in fig. 11.
fig. 11- Securing to the floor
6.3 Aeraulic connections
In addition to the spaces indicated in 6.1, the heat pump.re-
quires adequate air ventilation.
Create a dedicated air channel as indicated in fig. 12.
WARNING! The depression of the room due
to the expulsion of air to the outside, involves
air aspirations from the frames (doors and
windows). Prepare an air inlet (Ø 160mm) from
the outside to avoid sucking in the air from the
heated volume. In winter, the air that enters from
the air intake can cool the room.
It is also important to ensure adequate ventilation of the room
containing the unit. An alternative solution is shown in the figure
below (fig. 13): it provides for a second ducting that takes air
from the outside instead of directly from the inside room.
cod. 3541T640 - Rev. 05 - 12/2021
Mandatory air
inlet D.160 mm
Internal
compartment
fig. 12- Example of air outlet connection
Internal
compartment
fig. 13– Example of air outlet connection