To enter the temperature setting mode, proceed as follows:
• Switch on the machine keeping the coffee dispensing but-
tons pressed for 5 seconds:
▪ ⓬ for the Manual version
▪ ➌ and ❹ for the Automatic version.
NOTE: The machine set up permits to set the
temperature on 3 levels, at intervals of 3°C
(-3°C, Standard, +3°C).
MANUAL version
Once having entered temperature setting, select by means
of the coffee dispensing button ⓬.
AUTOMATIC version:
Once having entered temperature setting, select by means
of the short coffee dispensing button ⓬.
The three temperature levels are shown by the Blue LED
and/or the Red one, as follows:
TEMPERATURE LEVEL
Minimum
Standard
The temperature level changes every time the coffee dispensing button is pressed.