Descargar Imprimir esta página

turck PSU67-3P-1H2-1H0-24250 Guia De Inicio Rapido página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
PSU67-3P-1H2-1H0-24250
EN
Quick Start Guide
PSU67-3P-1H2-1H0-24250
Other documents
The following additional documents are available online at www.turck.com:
Data sheet
EU declaration of conformity (current version)
For your safety
Intended use
The power supply unit PSU67-3P-1H2-1H0-24250 is a stand-alone power
supply for three-phase mains systems for indoor use.
The device may only be used as described in these instructions. Any other
use is not in accordance with the intended use. Turck accepts no liability for
any resulting damage.
General safety notes
The device must only be mounted, installed, operated and maintained by
trained and qualified personnel.
The device is a "Class of Protection I" equipment according to IEC 61140.
The device is designed for pollution degree 3 areas in controlled environ-
ments.
Only use the device with additional protective devices in the area of
personal and machine protection.
Operate the device exclusively within the technical specifications.
Do not connect the negative potential of any output externally to PE.
Do not use without a proper PE (Protective Earth) connection.
Product description
Device overview
S. fig. 2: Dimensions, s. fig. 3: Block diagram
Functions and operating modes
The power supply provides a stabilized and galvanically separated PELV/
ES1 output voltage at the output. The negative potential of the outputs is
permanently connected to PE within the unit.
The output is electronically protected against no-load, overload and short
circuit and can supply any kind of loads, including unlimited inductive and
capacitive loads.
When connecting loads with a capacitance > 100 mF, the output is switched
off due to overload. The device switches to intermittent mode (hiccup mode)
and automatically enables the output again after the overload has been
eliminated.
The device is equipped with an over-temperature protection. In case of a
over temperature, the device shuts down and starts automatically again
after cooling off.
In case of an internal defect, a redundant circuit limits the maximum output
voltage to 32.5 V. The output is shut down and restarts automatically if the
defect is eliminated.
Installing
General installation instructions
The enclosure of the device provides a degree of ingress protection of IP65
and IP67 when installed with all mating connectors firmly connected. The
housing offers protection against electrical, mechanical and fire hazards.
The device is generally designed for altitudes up to 5000 m (16400 ft). Above
2000 m (6560 ft), output current and overvoltage category must be reduced.
When using the device in TN, TT and IT networks the following applies:
TN, TT mains systems with earthed neutral and IT star mains systems with
insulation monitoring: Use in zones of overvoltage category III up to an
altitude of 2000 m (6560 ft), use in zones of overvoltage category II up to
an altitude of 5000 m (16400 ft)
TN, TT, IT delta mains systems or IT star mains systems without insulation
monitoring: Use in zones of overvoltage category II up to 2000 m (6560 ft)
The device uses convection cooling. An external fan is not necessary.
Special mounting instructions
CAUTION
Sharp edges on the back of the device
Risk of injury
Mount the devices on a sufficiently large, even surface so that all sharp
edges are covered.
Mount the device vertically with the connection level facing downwards
on a flat surface using two M4 screws each suitable for the surface at the
upper and lower mounting holes.
Ensure that no moisture or dirt gets into the connections during installa-
tion.
Other mounting orientations: reduce the output current.
Do not obstruct airflow. Do not cover ventilation fins.
Observe the minimum installation clearances: 50 mm on top and bottom,
10 mm on the front and 10 mm left and right side.
Connecting
Connect the device according to "Wiring diagrams".
Mating connectors
Input voltage (XD1): HANQ4/2, 4 contacts + 2 control contacts
Relay OK signal (X0): standard M12 female connector, 5 pole A coded
Output voltage (XD2): HANQ4/0
Suitable accessories can be found in the Turck product database at
www.turck.com. The accessories are not part of the scope of delivery.
Do not apply return voltages from the load to the output higher than 35 V.
Do not connect outputs or devices in parallel.
PSU67-3P-1H2-1H0-24250
IP67 Power Supply
Quick Start Guide
Doc. no. 100034423
Additional
information see
turck.com
38
182 [7.17]
20
[1.50]
[0.79]
168.2 [6.62]
163.7 [6.45]
107
[4.21]
4.5
[0.18]
HAN-Q4/2
HAN-Q4/0
M12 × 1
mm [Inch]
Input
L1
Fuse
1
L2
Filter
2
PFC
Power
L3
3
Recti er
Converter
nc
4
Inrush Current
PE
5
Limiter
XD1
Output
Power
Temperature
Output
Manager
Shutdown
OVP
U
/V
Out
28
adjustment range
24
13
0
0
12.5
© Hans Turck GmbH & Co. KG | 100034423 2022-02
59 [2.32]
56.3 [2.22]
183
[7.21]
232.2
[9.14]
Output
+
3
Filter
2
XD2
LED bar
Status
Set
1
DC OK
ROK
4
X0
A: continuous current
B: intermittent current
A
B
23 27
I
/A
Out

Publicidad

loading

Productos relacionados para turck PSU67-3P-1H2-1H0-24250