B
C
Knockout
hole
10. Close the diffuser (B), press the lock switch to "LOCK" position and cover with the external end caps (C).
C
C
contInuous InstallatIon
The continuous mounting steps are based on the suspended mounting.
1. Punch out the knock out holes on the end of each wrap light housing (A) where two fixtures will connect, then open the
diffuser (B) of each fixture. Feed the wires by referring to the steps of chain mounting for each fixture.
2. Insert a 7/8in. outer diameter fitting threaded coupler (not included) through both open knock out holes. Secure the
coupler with 2 threaded nuts (not included).
3. Insert one end of the jumper wires (GG) into the wire connectors from the first fixture, then run jumper wires (GG)
through the threaded coupler, and insert the other end into the wire connectors from the next fixture to make the
electrical connections.
4. Connect the two fixtures using the joint metal part (AA)and thumb screws (CC).
5. Refer to chain mounting steps to finish the stem installation.
NOTE: Multiple light fixtures can be connected, up to a maximum of 8 Lights. Do not exceed 400 total watts for
interconnected lights.
NOTE: If planning to continuously mount multiple fixtures using a single power source, feed the electrical wires from
the electrical box through the center of the conduit and then through the open knock out hole in the fixture housing (A).
Lock
Slot
3
2
Conduit
(not included)
B
3
5
E
1
A