4. TECHNICAL FEATURES
No -
Output
Input
load
current
Model
Voltage
output
range
(V)
Voltage
(V)
MIS 120
220
60
15-120
* These values were obtained using Constant supply equal to 220 V in the input of the equipment.
** Selectable values. For further information about electrode variations, refer to the manufacturer's catalog.
TABLE 1 – TECHNICAL FEATURES
European Standard for welding equipment
EN 60974-1
Manual arc with limited life cycle
Single-phase transformer
U
Nominal Input Voltage (V)
1
I
max
Maximum value of input current (A)
1
I
Effective value of input current (A)
1eff
Safety device (fuse)
U
Nominal open circuit voltage (V)
0
TABLE 2 - LEGENDS
5. MAIN COMPONENTS
3
FIGURE 1
6. APPLICATION
6.1 Welding in electrode mode (MMA)
Ground Cable Connection – To weld, mount the ground cable Connector to the Negative (-) pole;
Electrode holder connection – the electrode must be connected to the electrode holder in positive (+) pole.
6.1.1 MMA welding process
•Fix the ground cable next to the part to be welded;
Turn on the equipment using the knob (2);
Adjust the potentiometer (2) according to the diameter of the electrode and the material to be welded. The current value will be shown on the
digital display (6);
Place the electrode in the electrode holder;
Position the electrode to the part to be welded and start work;
When the electrode is at 1cm to 2cm, replace it with a new one.
ATTENTION: During the welding process the electrodes reach high temperatures. Always wear suitable gloves to avoid burns.
Input
current
Hz
Type
range
(A)*
(A)
25
50-60 Single-phase
I
2
IP23
H
V
1
2
AWS
Work
Level of
6013
factor
Protection
Electro-
(%)
de (mm)
40
1,6 - 3,2
IP23
Legend:
Welding current
Symbol for manual welding with coated electrodes
Protection Rate
Insulation Rate
Do not throw electrical tools in regular garbage
Do not use the equipment in humid places or exposed to rain.
The equipment must be used in dry places
Volts
4
5
6
7
FIGURE 2
20
Max.
Circuit
Wire
distance from
breaker
(mm²)
switchboard (m)
(A)
15
6
50
Danger of electric shock
A
Amperes
Hz
Hertz
W
Watts
Alternate current
Direct current
Ground Terminal
Safety warning symbol
Read the instruction manual
1. Electrode holder
2. Current adjustment potentiometer
3. Negative output terminal
4. Equipment on indicator
5. Overheat / fault indicator
6. Digital display of output current
7. Power cord
Dimensions
W e i g h t
(mm)
(kg)
260 x 80 x 300
2,5 / 1,4