Step 10
Place the sash seal (B) between the lower and upper window sash.
Operation
Performance test
DANGER
Risk of electric shock! The power plug of this product
provides LCDI protection (Leakage Current Detection and Interruption).
If the LCDI is de-activated this indicates an arcing fault. Unplug and
check the power cord and product. If no damage is visible, reset the
product by pressing the RESET button (P). If the LCDI de-activates
again, a hazardous condition may be present and the product should
be discarded or returned to an authorized service facility for examination
and/or repair.
CAUTION
Risk of electric shock! Run performance test before
each use.
Press the RESET button (P).
Connect the power plug to a wall outlet. The power plug indicator (O)
lights up.
Press the TEST button (Q). The RESET button (P) should pop out
and the indicator on the power plug (O) should go off.