Descargar Imprimir esta página

Craftsman 919.165383 Manual Del Propietário página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

How to Start
1.
Set the On/Off switch to "On" and
allow tank pressure to build. Motor
will stop when tank pressure reach-
es "cut-out" pressure.
2.
Turn regulator knob clockwise to
increase pressure and stop when
desired pressure is reached.
Customer Responsibilities
Check Safety Valve
Drain Tank
power is on. When performing
maintenance, you may be exposed
to voltage sources, compressed air,
or moving parts. Personal injuries
can occur. Before performing any
maintenance or repair, disconnect
power source from the compressor
and bleed off all air pressure.
NOTE: See Operation section for the
location of controls.
To Check Safety Valve
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.
wear certified safety equipment:
ANSI Z87.1 eye protection (CAN/CSA
Z94.3) with side shields
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced with
the same type of valve.
1000002204
MAINTENANCE
Before
each
use
X
Unit cycles
automatically when
Risk of Bursting.
If the safety valve
Risk from Flying
Objects. Always
is noticed, stop the compressor
immediately and have it checked by
a trained service technician.
The compressor is ready for use.
Daily
or after
each
use
X
To Drain Tank
from noise. Air tanks contain high
pressure air. Keep face and other
body parts away from outlet of
drain. Use ANSI Z87.1 eye protection
(CAN/CSA Z94.3) when draining as
debris can be kicked up into face.
Use ear protection [ANSI S12.6
(S3.19) hearing protection] as air
flow noise is loud when draining.
1.
Set the On/Off switch to "Off".
2.
Turn the regulator knob counter-
clockwise to set the outlet pres-
sure to zero.
3.
Remove the air tool or accessory.
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately 20
psi. Release safety valve ring.
5.
Drain water from air tank by open-
ing drain valve on bottom of tank.
in the air tank. If not drained, water
will corrode and weaken the air tank
causing a risk of air tank rupture.
14 - ENG
If any unusual
noise or vibration
Risk of Unsafe
Operation. Risk
Risk of Bursting.
Water will condense

Publicidad

loading