Each air compressor is carefully
checked before shipment. With
improper handling, damage may
result in transit and cause problems in
air compressor operation.
Immediately upon arrival, check
equipment for both concealed and
visible damages to avoid expenses
being incurred to correct such
problems. This should be done
NOTE: Photographs and line drawings used in this manual are for
reference only and do not represent a specific model.
Become familiar with these terms
before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per
minute; a unit of measure of air
delivery.
PSIG: Pounds per square inch
gauge; a unit of measure of pressure.
Code Certification: Products that
bear one or more of the following
marks: UL, CUL, ETL, CETL, have
been evaluated by OSHA certified
independent safety laboratories and
meet the applicable Underwriters
Laboratories Standards for Safety.
Cut-In Pressure: While the motor
is off, air tank pressure drops as
you continue to use your accessory.
This air compressor pump is capable
of running continuously. However, to
prolong the life of your air compressor,
it is recommended that a 50%-75%
Accessories for this unit are available at the store the unit was purchased.
A07982
ON-RECEIPT INSPECTION
GLOSSARY
DUTY CYCLE
ACCESSORIES
8 - ENG
regardless of any visible signs of
damage to the shipping container.
Report any damages to carrier and
arrange for inspection of goods
immediately.
For the location or a listing of the
nearest Authorized Warranty Service
Center, call our toll free number at
1-800-888-2468.
When the tank pressure drops to a
certain low level the motor will restart
automatically. The low pressure at
which the motor automatically restarts
is called "cut-in" pressure.
Cut-Out Pressure: When an air
compressor is turned on and begins
to run, air pressure in the air tank
begins to build. It builds to a certain
high pressure before the motor
automatically shuts off - protecting
your air tank from pressure higher
than its capacity. The high pressure
at which the motor shuts off is called
"cut-out" pressure.
Branch Circuit: Circuit carrying
electricity from electrical panel to
outlet.
average duty cycle be maintained; that
is, the air compressor pump should
not run more than 30-45 minutes in
any given hour.