Section 4: Opecation
For a more permanent
sheiter_ buiid a structure
that wili
enciose three sides and the top of the generator.
7.
Hake sure entire muffleroside of generator
is exposed_
as shown in Figure i0.
[MPORTANT:The
generator
must be at ieast 5 ft.
(i 52 cm) from structures
having combustibie walis and/or
other combustibie
materiais. Leave at ieast 3 ft. (92 cm) ali
around generator
inciuding overhead_ for adequate cooling_
maintenance and servicing.
8.
Face exposed end away from wind and elements.
9.
Structure
shouid hoid enough heat created by the
generator
to prevent icing probiem.
i 0. Start and run engine outdoors.
i. Keep exhaust gas from entering a confined area
through windows_ doors_ vendhtion
intakes or other
openings.
WANNING
Operate
generator
ONLY outdoors,
Keep exhaust gas from entering
a confined area through
windows, doors, ventilation
intakes or other openings.
DO NOT operate generator
inside any building or enclosure,
including the generator
compartment
of a recreational
vehicle
(RV),
2. DO NOT enciose generator
any more than shown in
Figure i 0.
3. Remove sheker when temperatures
are above 40°F
[4°C1.
i 4. Turn engine OFF and iet cooi two (2) minutes before
refuelling.
GENERATOR
ADAPTER
CORD
SET
The generator
is equipped with a 25' generator
adapter
cord set designed for a 240 Voit_ 30 Amp grounded neutrai
circuit (Figure i i).The generator
adapter cord set provides
a convenient suppiy of emergency
power into your dwelling
so that your generator
can be operated
safeiy outside.
The maximum load on each oudet is 20 Amps.The
maximum total load on both yellow wire oudets or both
black wire oudets is 30 Amps.
NOTE:
Follow ail safety precautions
when connecting any
extension
cord or device to the generator,