TROUBLESHOOTmNG
Problem
No AC output
is avaimabme, but
generator
is running.
Generator
runs
good at no=load
but "bogs"
down"
when
loads are
connected.
Generator
wHm not start; or starts
and runs
rough.
Cause
H.
One of the circuit
breakers
is
open.
2.
FauHt in generator.
3.
Poor connection
or defective
cord
set.
4.
Connected
device
is bad.
I.
Short
circuit
in a connected
load.
2.
Generator
is overloaded.
3.
Shorted
generator
circuit.
I.
10Amp
in=line fuse is blown.
2.
Discharged
battery.
Correction
I.
Reset circuit breaker.
2,
ContactAuthorized
service facility,
3,
Check and repain
3.
Failed battery.
Generator
shuts down
during
Out of gasoline.
operation.
Generator
lacks power.
Load is too high.
See "Don't
Overload
Generator".
4.
Connect
another
device that is in
good condition.
I.
Disconnect
shorted
electrical
load.
2.
See "Don't
Overload
Generator".
3.
ContactAuthorized
service
facility.
I.
Replace fuse.
2.
Jump start generator
and/or
charge
battery.
3.
Replace battery.
Fi[[ fuel tank.