User Manual
CHARGING SETTINGS
To set the charger in relation to the battery that needs to be charged, it is necessary to carry out few steps. Please
note a service technician only can perform these functions!
The charging curve is set when the battery charger is not connected to the battery.
To enter the programming menu, disconnect the battery and once "No Battery" message appears, press and hold the
and
keys together for 10 seconds (the yellow DL2 LED ON indicates the programming Phase) . You can now
use the keys to scroll through the various parameters. The following parameters can be changed: Type of curve,
Voltage, Current
After selecting the parameter you want to change, press
red DL3 LED that turns on) and use the
Press
again to confirm the value set (the red DL3 LED will turn off ).
After setting the values, exit the setup menu by selecting "Programming Save and Exit" and press
display shows " PARAMETERS SAVED " and the parameters are saved in EEPROM.
If the operator has entered into the programming section and is still in it without operation, the battery charger
automatically goes back to the display showing the charging status after about 30 seconds.
LED MESSAGES DISPLAYED
Ref.
Messages reported
Start
Auto-start execution
F1
Phase 1: Initial charge at constant current
F2
Phase 2: Final charge at constant voltage
F3_I (*)
Phase 3: Final charge at constant current
F3_U (*)
Phase 3: Final charge at constant voltage
F4
Charging complete
Where:
OFF =
the LED is off
ON =
the LED is steady
BLK =
the LED is blinking
Note (*): The sequence of Phases and relative messages varies according to the curve.
10
to activate the option to edit the value (indicated by the
and
keys to set the desired value.
DL3 LED (red)
OFF
ON
ON
OFF
OFF
OFF
DL2 LED (yellow)
DL1 LED (green)
OFF
OFF
OFF
ON
ON
OFF
, so that the
OFF
OFF
OFF
OFF
OFF
ON
D00240-02