7.
FAULTS
The information shown below aims to help with
the identification and correction of any anomalies
and malfunctions which could occur during use.
Some of these problems can be resolved by the
Problem
The refrigerator unit does not start
The refrigerator unit functions
continuously, cooling insufficiently
The refrigerator unit does not stop
Presence of ice inside the
evaporator
Appliance noise
user. For the others, precise competency is
required and they must therefore only be carried
out by qualified staff.
Causes
End of defrosting
Switch-off by means of master
switch
No voltage
Other causes
Room too hot
Dirty condenser
Insufficient door sealing
Insufficient quantity of
refrigerant gas
Hot gas valve partially open
Resistances always inserted
Condenser fan at a standstill
Evaporator fan at a standstill
Probe faulty
Remote-thermostat or
thermostat faulty
Drain pipe blocked
Appliance not level
Hot gas valve failure
Resistances not functioning
Persistent vibrations
9
ENGLISH
Solutions
it starts after a pause of 3 minutes
re-started, starts up after 3 minutes
check plug, sockets, fuses and
electric mains
If the problem persists,
contact the after-sales centre.
air the environment
clean the condenser
check the gaskets
Contact the after-sales
centre.
Contact the after-sales
centre.
check timer (only on models with
electric defrosting)
Contact the after-sales
centre.
Contact the after-sales
centre.
Contact the after-sales
centre.
Contact the after-sales
centre.
disassemble and re-assemble the
drain unit after having checked its
cleanliness
use the adjustable feet to level
Contact the after-sales
centre.
check defrosting activation (only on
models with electric defrosting)
check there is no contact between
the appliance and other objects
inside or outside