Descargar Imprimir esta página

Racer SERENITY Instrucciones De Uso página 40

Publicidad

Idiomas disponibles

Idiomas disponibles

Before carrying out any service on the item, check:
Disconnect the pins from the mains or by means of a two poles switch with 3 mm minimum distance between the
contacts.
Relieve all the pressure from the peristaltic pump and injection tube.
Drain or flush all dosing liquid from the peristaltic.
In case of any losses in the hydraulic pump (rupture of the injection valve, filter, pipes), you have to stop operation of the pump
depressurize the discharge pipe and then proceed with the maintenance using appropriate security measures (gloves, goggles,
overalls, etc..). Dosaggio di liquidi nocivi e/o tossici.
Toxic and/ or dangerous l iquid dosage
To avoid risk from contact with the hazardous liquids or toxic fumes, always adhere to the notes in this instruction manual:
Follow the instructions of the dosing liquid manufacturer.
Check the hydraulic part of the pump and use it only if it is in perfect condition.
Use only the correct materials for the tubing, valves and seals to suit the liquid to be dosed; where possible shield the
tubing with PVC conduit.
Before disconnecting the metering pump, make sure to flush out and neutralize the pump head with the proper reagent
liquid.
Assembly
All metering pumps are normally supplied fully assembled. For greater clarity, please consult the exploded view of the pump
appended at the end of the manual, which shows all the pump details and a complete overview of all the pump components. These
drawings are in any case quite indispensable whenever defective parts have to be re-ordered. For the same purpose, the appendix
also contains other drawings showing the hydraulic parts (pump head and valves).
Dismantlement
Proceed as follows before you dismantle the pump or before performing any other operation on it:
Disconnect the pins from the mains or by means of a two poles switch with 3 mm minimum distance between the
contacts.
Relieve all the pressure from the peristaltic pump and injection tube.
Drain or flush all dosing liquid from the peristaltic.
This operation calls for special attention, and you should therefore consult the drawings in Appendix and Chapter "RISKS"
before you commence work.
PERISTALTIC PUMP Racer SERENITY SERIES
Operating principle
Peristalsis is a wave of automatic contractions propelling contents along channel or tube, this led to a peristaltic action. By
mechanical simulation of biological peristalsis rollers crush tube walls togheter to form a seal while roller moves along the tube, then
the previously compressed tube regains original form and sucks fluid into the formed vacuum. The fluid will follow the roller until
tube is not compressed any more, then to avoid a flow back a second roller compress the tube, pushing the fluid out of the pump
and repeating the suction action while the pump continues to operate the rollers which are fitted on a special rotor create suction lift
and outlet pressure.
40
ENGLISH

Publicidad

loading

Productos relacionados para Racer SERENITY