REGOLAZIONE E PULIZIA
CONTENTS
Packing:
1. Unpacking instructions.
Fitting of the accessories:
2. Assembling the protective glass dome.
Cleaning:
3. Internal cleaning.
4. External cleaning.
Connections and control:
5. Connection to the mains.
6. Control.
WARNINGS
It is most important that this instruction booklet is kept together with the appliance both for future reference and for
reasons of safety. 1. Adults should operate this appliance only. Do not allow children to use the controls or play with it.
2
. It is forbidden to modify in any way the main functions and characteristics of this appliance. . The electrical installation of
the appliance should be carried out by a qualified electrician or other competent person. . Never attempt to carry out repairs
unassisted. Inexpert repairs can cause serious damage and malfunction. . Assistance has to be provided by an authorized
engineer only. Always use original spare parts. . This appliance is not suitable for the storage of basic commodities not
including food-stuffs. . The manufacturers of this appliance accept no responsibility for the consequences of misuse in
7
contravention of these safety instructions. It further reserves the right to carry out improvements without prior notice. 8. Avoid
installing the cabinet directly in line with sunlight. . Nevere install the appliance near sources of heat, such as radiators,
stoves, etc.
10
. Keep the ventilation grills free from obstruction for at least 30 cm.
the shelves and grills do not hang over the edges.
evaporator, we recommend stopping the compressor and placing the goods in special refrigerated containers, kept at the same
temperature, until defrosting is completed;if this is not carried out the compressor will continue to operate leading to a
wasteful consumption of electricity and poor performance. 13. These appliances are not for built-in use.
1. UNPACKING INSTRUCTIONS
CARDBOARD PACKAGING 1
N.B.: on the models C and SS, be careful of the glass placed in the upper part of the appliance and fixed with sticky tape.
3
. Remove the protective cardboard panels. . Place the appliance on a horizontal level surface. . Make sure there is nothing
left inside the packaging before disposal.
2. ASSEMBLING THE PROTECTIVE GLASS DOME
1.
Slide the side glass in along the runners.
equipped with bushings (B).
screws (A) equipped with bushings (B) (See picture 2).
3. INTERNAL CLEANING
1. Wipe the sides of the appliance with a sponge dipped in water and sodium bicarbonate. Dry with care. (COLD models).
2.
Clean the tub with a soft, damp sponge.
4. EXTERNAL CLEANING
1.
Remove the protection film from the stainless steel sides. . To clean use the same products used for the inside. . Dry
using a soft clean cloth.
5. CONNECTION TO THE MAINS
1. Ensure that mains voltage and frequency are the same as those stated on the rating plate (A) attached to the side of the
appliance. . Ensure that the supply socket has the following characteristics:
2
the nominal current as set out on the rating plate.
(circuit breaker) with In = nominal value as stated on the rating plate with sensitivity Id = 30 mA. . The supply cable to the
appliance is H05 VVF, designed for internal use. . Insert the plug into the socket (Do not use triple or adapter) (See pict. 3)
6. CONTROL (R290 pag.6)
The controls of the appliance are on the top right hand side.
regulate the internal temperature of the appliance. a) Press the key
will be shown (on the display), while pressing key
"DOWN" to reduce the temperature (See picture 4).
7. Checking the correct functioning.
Regular maintenance:
8. Cleaning the filter (COLD models only).
9. Internal cleaning.
Occasional maintenance:
10. Replacement of the heating element (DRY models only).
Diagrams:
Wiring diagram (Pg. 4-5)
Diagram of refrigeration unit (COLD models only) (Pg. 6)
6
9
12
. If damp air or products to be refrigerated should cause ice to form on the
. Cut the strap.
2.
Open the cardboard box and remove the appliance, pulling upwards.
4
6.
Separate the different packaging materials to facilitate disposal. (See picture 1)
2.
Fix the Plexiglas cubes to the glass sides using the screws supplied (A)
3.
Position the upper glass on the side glasses.
DO NOT USE WATER
c)
It complies with the IEC regulations: magnetothermic differential switch
4
4 "UP"
5
11
. Ensure that the products displayed on
(models C-SS only)
4.
Fix the upper glass to the cubes using the
(DRY models).
3.
2
a)
it is properly earthed.
1. 0/I Switch:
to switch on the appliance.
3 "P"
(once only) and the set temperature of the appliance
a few times the temperature will be increased. Press key
9
3
4
5
Dry using a soft clean cloth.
b)
It is appropriate for