Installer setup tables
Setup function
17 External fossil fuel kit
(EIM only)
18 Dual fuel heat pump
control (EIM only)
20 Droop temperature
(dual fuel) (EIM only)
21 Dual fuel upstage to
furnace timer (EIM
only)
22 Outdoor air sensor?
(EIM only)
24 Heat pump
compressor lockout
(balance point) (EIM
only)
25 Heat pump
auxiliary lockout
(EIM only)
26 Auxiliary heat control Applies only to Model TH6320
27 Maximum heat
setpoint
28 Minimum cool
setpoint
32 Temp. display offset
(indoor)
33 Temp. display offset
(outdoor)
35 Humidity display
offset (outdoor)
Français : voir la page 9 • Español: vea la página 17
Settings & options (factory default in bold)
1
External fossil fuel kit controls backup heat
0
Thermostat controls backup heat (outdoor sensor required)
1
Droop control**
0
No droop control**
2
Droop control with Aux Heat Lockout**
2
Auto temperature droop 2° F (1° C)
[Options: 2 to 5 (2 to 5° F / 1 to 2.5° C)]
1
1 hour**
[Options: 0 (off) to 16 hours]
0
No
1
Yes
0
No heat pump compressor lockout**
1
5° F (-15° C)
2
10° F (-12° C)
3
15° F (-9.5° C)
4
20° F (-6.5° C)
5
25° F (-4° C)
6
30° F (-1° C)
0
No heat pump auxiliary lockout**
1
5° F (-15° C)
2
10° F (-12° C)
3
15° F (-9.5° C)
4
20° F (-6.5° C)
5
25° F (-4° C)
6
30° F (-1° C)
7
35° F (1.5° C)
0
Comfort**
1
Economy
90
Max. heat temperature setting is 90° F (32° C)
[Options: 40°F to 90°F (4.5 °C to 32 °C)]
50
Min. cool temperature setting is 50° F (10° C)
[Options: 50°F to 99°F (10 °C to 37 °C)]
0
Thermostat displays actual temperature
[Options: -3 to +3°F offset (-1.5 to +1.5°C)]
0
Thermostat displays actual temperature
[Options: -5 to +5°F offset (-2.5 to +2.5°C)]
3
Thermostat displays actual humidity
[Other options: 0 = -15%, 1 = -10%, 2 = -5%, 4 = +5%,
5 = +10%, 6 = +15% offset]
7
35° F (1.5° C)
8
40° F (4.5° C)
9
45° F (7° C)
10
50° F (10° C)
11
55° F (13° C)
12
60° F (15.5° C)
8
40° F (4.5° C)
9
45° F (7° C)
10
50° F (10° C)
11
55° F (13° C)
12
60° F (15.5° C)
13
65° F (18.5° C)
5
** See page 6
69-2092EFS—11