System test
Follow the procedure below to test for proper operation.
To begin, press and hold the
until the display changes (about 3 seconds).
System test
02 Wireless test
04 Return air sensor
10 Heating system
20 Emergency heating
system
30 Cooling system
40 Fan system
70 Thermostat information
(for reference only)
CAUTION: EQUIPMENT DAMAGE HAZARD. Compressor protection (minimum off
time) is bypassed during testing. To prevent equipment damage, avoid cycling the
compressor quickly.
Français : voir la page 9 • Español: vea la página 17
M28488
and
buttons
s
t
System status
0
Off
1
Test radio signal (after a brief pause, screen displays 1-10 to show
signal strength; 5 or higher recommended)
Screen displays return air temperature if device is installed and
working properly (EIM only)
0
Heat and fan turn off.
1
Heat turns on
2
Stage 2 heat turns on
3
Stage 3 heat turns on
0
Heat and fan turn off
1
Heat and fan turn on
0
Compressor and fan turn off
1
Compressor and fan turn on
2
Stage 2 compressor turns on
0
Fan turns off
1
Fan turns on
71
Software revision number (major revisions)
72
Software revision number (minor revisions)
73
Configuration identification code (major)
74
Configuration identification code (minor)
75
Production configuration date code (week)
76
Production configuration date code (year)
7
System test number
02
Done
Back
Press
or
to check system status
s
t
NEXT
Press
to advance to next test
DONE
Press
to terminate system test
System status
0
Next
M28489
69-2092EFS—11