Always use your compressor on a flat surface.
The start switch is situated on the cover of the pressure switch.
Turn the switch to position "0" on (Fig.2).
Insert the plug into the socket and start the compressor turning the switch to position
"1".
The compressor working process is automatic.
The pressure switch stops the compressor when the pressure in the tank
reaches the maximum value allowed and starts it again when the pressure
drops to the minimum value (see values on pag.53)
Adjust the outlet air pressure operating on the reducer-filter (Fig.3)
Pressure is shown on the gauge placed on one side of the regulator.
The compressor power lines or eventual extensions must have the wire section propor-
tioned to the lenght.
Be aware that compressor motor head and its outlet hose can get high tem-
perature. Do not touch these parts to avoid the risk of thermal shock.
Each compressor unit is equipped with a thermal protector stopping the
compressor in case of overheating.
In case of protector tripping, the protector will reset automatically after
15/20 minutes, so the compressor will restart automatically.
This compressor unit is not able to restart when its outlet pipe is under
pressure so is equipped with a pressure relief system having the purpose
to release the pressure inside the compressor outlet pipe when it stops run-
ning (a valve placed below the pressure switch).
Perform the test as follows:
1.Empty the compressor air tank
2.Close the compressor outlet on the tank and check that the drain cap is closed
3.Start the compressor and check the time elapsing between starting and automatic
switching off
4. Check that there are no leaks on connections.
5. check max. pressure
Tank filling times from 0 to p max for the models are reported on pag.53.
OPERATING INSTRUCTIONS
4.1 - START UP
4.2 CHECK OF FILLING UP TIME