Related information
2.4.1 Nameplate
3.1 Inspecting the product
7. Commissioning the product
Check the following before the first startup:
1. The solar panels are installed according to the
installation and operating instructions and local
regulations.
2. The electrical connections are made according to
the installation and operating instructions and
local regulations.
3. When connecting the DC supply, make sure that
the correct wiring of +/- is made to both
PowerAdapt and RSI.
4. The pump is installed according to the relevant
installation and operating instructions.
5. Make sure that all earthing is connected to a
common potential.
7.1 Grundfos GO Remote
The product is designed for wireless radio or infrared
communication with Grundfos GO Remote.
Grundfos GO Remote enables functions and access
to status overviews, technical product information and
current operating parameters.
Use Grundfos GO Remote together with Grundfos MI
301 mobile interface:
Pos. Description
Grundfos MI 301:
Separate module enabling radio or infrared
1
communication. Use the module together with
an Android or iOS-based smart device
through Bluetooth connection.
10
1
+
8. Starting up the product
RSI needs to be configured according to the installed
motor and pump. See the installation and operating
instructions for RSI.
Check that RSI with the motor and the pump operates
according to the specifications.
8.1 Operation
The system ensures an automatic operation. When
the system is powered up, the DC source powers
directly the RSI. The AC source is connected with a 3
minutes power-on delay. The 3 minutes delay
protects against voltage transients during start-up in
the generator application.
8.2 Derating and ambient temperature
Under maximum operation conditions, the ambient
temperature cannot exceed 40 °C. Higher ambient
temperatures are allowed, but only with a derating
current indicated in the figure below.
150
100
75
A
50
25
-10
0
10
Ambient temperature and rated current
Pos. Description
A
Rated output current (%)
B
Ambient temperature (°C)
20
30
40
50
B