flexible piping.
6. In the case of flexible piping, the pump must be supported by a cable made of material which is not
liable to deteriorate in the long term.
The cable should be passed through the two grommets (7) on the cover.
7. Check the pump, motor, cable, or the socket connection whether they are in good condition.
All the screws connected should be tightened.
8. After connecting the pump to the power supply, let the motor run idle for a few seconds to check
the pump is correctly starting, operating, and motor is running in proper direction.
9. Note:- you may use plastic or rubber clips to support the power cord to the discharge at regular
intervals of 3 meters (10feet).
- ensure that discharge pipe joints are tightened to prevent loosening due to the torque of motor.
4.6- Operation
1. Before starting the pump, check:
- the direction of motor rotation: trial-run the pump for no more than 1 minute to check the motor
rotates counter clockwise (when looking at pump from above);
- that electrical connection is correctly setup;
- that the electrical cable and drain hose are properly laid to avoid accidents;
- that check valves (if fitted) are opened
2. Check all joints of water pipe to determine water does not leak and soak any electric component.
3. Start the pump to check the ampere value and the condition for water to be discharged by the pump.
If it is under normal conditions; then you may let the pump continue operating until water is clean and
unblocked.
4. After starting, check that motor operates and stops without noise and vibrations.
5. After operating for at least 15 minutes, check pump output, motor input, lowest level of water and
other characteristics.
All above should be steady and in accord with the assigned characteristics.
6. Check the pump performance whether the capacity of pump should be in 0.7 ~1.2 times rated
scope, otherwise the pump operating is in abnormal condition, so the motor may overheat, even burn.
7. If any abnormal phenomenon appears, such as abnormal sound, lack of water or intermittent flow,
you should stop the motor immediately and investigate the reasons.
Regularly check water level during pump operating so as not to fall under pump recommended lower
level, as the pump cannot operate if water level is low.
Pay attention during cold temperatures (when air temperature is below 4°C) to prevent frost-broken
the pump body.
8. Do not wash, swim and pasture domestic animals in water within the pump working area for about
two square meters.
9. Strictly forbid anyone to touch the pump by hand when under power so as to avoid accident.
V. OPERATION
5.1- Intended use
1. This submersible pump can be used for domestic, industrial or farming applications, for pumping
clear water with particles in suspension that are less than 0.2mm or 0.5mm in diameter (according to
pump model).
2. The pump is fully submersible: the immersion depth must not exceed 15m (refer to
characteristics table).
3. The pump should not be used for sucking up liquids or materials that are corrosive,
combustible/flammable or explosive.
4. The temperature of liquids sucked up should not exceed 35°C.
5. Any other use, other than that described in the instructions, is likely to damage the pump and to
put the user in serious danger.
Page 19 / 51