Technical Data - MAGLOGIX MagnaJig MX-1500 Manual De Instrucciones

Imán adherente conmutable
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Product-Number:
Designation:
Breakaway force:
(at 0° inclination to the load)
Max. load-bearing capacity:
(at 90° inclination of the load)
Max. load-bearing capacity:
(at 90° inclination of the load)
Dead weight of the unit:
Storage temperature:
Operating temperature:
Markings on the Magnetic Clamp
Detailed descriptions for the safe handling and proper operating conditions of the MX-1500 can be found on the
upper side of the Magnetic Clamp. If this label has been modified, damaged, or removed the manufacturer cannot
be held responsible for any personal injuries, property damage or accidents resulting from this fact. To meet full
compliance, the entire Magnetic Clamp must be returned to the manufacture for calibration and relabeling.
Start-up
You have received a completely assembled MagnaJig™ MX-1500 Magnetic Clamp and a detailed operating
manual. Please check the condition of all items upon receipt for any damage incurred during transport, and make
sure the delivery is complete. If you find any problems, please contact the manufacturer immediately.
1. Follow all safety instructions. Clean the workpiece in the area of attachment and the magnetic contact area
of the Magnetic Clamp (see Surface Quality).
Caution: At the beginning of the application, watch for any deformation of the workpiece to the magnetic
contact area when activating the Magnetic Clamp. If a small distance (air gap) forms between the magnetic
contact area and the workpiece, the Magnetic Clamp will not reach the stated holding force and could
detach itself. Please check for any air gap developing at the edges of the TiN-coated magnetic contact
area. This air gap can be tested by slipping a sheet of 20 lbs. (80g/m
into the gap:
Immediately stop the application!
Never exceed the dimensions and/or the load-bearing capacity of the values given in
Performance Data,
41200.MX-1500
MagnaJig™ MX-1500
Magnetic Clamp
>1320 lbs. on 3/8" AISI CRS 1020
30% of the breakaway force
440 lbs. on 3/8" AISI CRS 1020
5.81 lbs.
-22°F to+140°F
-22°F to+140°F
Table 2.
>600 kg on 10 mm S235
30% of the breakaway force
200 kg on 10 mm S235
2.64 kg
-30°C to +60°C
-30°C to +60°C
2
) paper into the gap. If the paper slips
Detailed
5

Publicidad