MAGLOGIX MagnaJig MX-1500 Manual De Instrucciones página 9

Imán adherente conmutable
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maximum operating temperature
The high-power permanent magnets installed in the Magnetic Clamp will maintain their load-bearing capacity up to
a maximum operating temperature of 176°F (80°C). Exceeding this maximum operational temperature may cause
irreversible damage.
Detailed Performance Data for the MX-1500 Magnetic Clamp
Values shown for the performance of the MX-1500 Magnetic Clamp are based on material A36 for the maximum,
vertical tractive force with 0° deviation from the load axis and additionally under a 90° inclined load in accordance
with EN13155. These values do not include any safety factor. The Magnetic Clamp will detach itself abruptly when
the load exceeds values given in Table 2.
Table 2
Thickness of
material
inch
0,08
1/8
0,16
0,20
1/4
5/16
>3/8
Thickness of
material
mm
2
3
4
5
6
8
>10
Breakaway force in lbs
Clean, flat, ground
surface
Air gap<0.004 inch
90°
250
75
400
120
700
210
890
267
1065
320
1275
383
1320
396
Breakaway force in kg
Clean, flat, ground
surface
Air gap<0.1 mm
90°
115
35
180
55
320
95
405
120
485
145
580
174
600
180
Rusty, slightly
scratched surface
Air gap =0.01 inch
Air gap =0.024 inch
90°
220
66
330
99
627
188
803
241
957
287
1100
330
1111
333
Rusty, slightly
scratched surface
Air gap =0.20 mm
90°
100
30
150
45
285
86
365
110
435
131
500
150
505
152
Irregular, rusty or
rough surface
90°
176
53
297
89
484
145
616
185
726
218
748
224
770
231
Irregular, rusty or
rough surface
Air gap =0.6 mm
90°
80
24
135
41
220
66
280
84
330
99
340
102
350
105
9

Publicidad

Tabla de contenido
loading

Tabla de contenido