CLEANING AND STORAGE
• DO NOT attempt to open the battery.
• DO NOT place the battery in the regular household trash.
• DO NOT incinerate.
• DO NOT place them where they will become part of any waste landfill or municipal solid waste stream.
• Cover the battery terminals with heavy-duty adhesive tape.
• If a leak develops, the released electrolytes are corrosive and toxic. DO NOT get the solution in
your eyes or on your skin, and do not swallow it.
• Dispose of the battery pack in accordance with local, state and federal regulations.
TROUBLESHOOTING
CAUSE
THE MOTOR WILL NOT RUN
The battery is not charged
The battery is not installed correctly
THE MOTOR OPERATES SLOWLY
The battery lacks sufficient charge
THE MOTOR RUNS, BUT THE UNIT WILL NOT BLOW
The impeller (fan) is damaged
The tube and/or blower opening is blocked
THE BATTERY DIES QUICKLY
The battery is not fully charged
The battery is old and will not hold a charge
THE BATTERY WILL NOT CHARGE
The charger is not plugged in
The battery is not fully inserted into the charger
base
The battery is too hot from use
NOTE:
For repairs beyond the minor adjustments listed above, locate your nearest authorized
service center by calling the Customer Support Department at 1-866-206-2707 (U.S.) or
1-877-696-5533 (Canada).
BLOWER*
Motor Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cordless, Battery-powered
Motor Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 V
Motor Speed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12,000 rpm
Maximum Blower Air Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 mph (201 km/h)
Weight (with Battery) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 lb 7 oz (2 kg)
BATTERY CHARGER*
Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electric, Corded
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 VAC
Amperage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 Amps
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 lb (0.45 kg)
* All specifications are based on the latest product information available at the time of printing. We
reserve the right to make changes at any time without notice.
REPLACEMENT PARTS
Part #
725-05270 (RM18VL) . . . . . . . . . . . . . . . . . . . . . . . . .
725-05272 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
SOLUTION
Charge the battery completely
Remove and reinstall the battery
Charge the battery completely
Have the unit serviced by an authorized service
center
Clear the blockage. Refer to Clearing a Blocked
Blower Tube in the Maintenance and Repair
Instructions section.
Charge the battery completely
Replace the battery
Plug the charger into a 120V 60hz AC source
Fully insert the battery into the charger base
Allow the battery to cool for 30 minutes before
placing it into the charger
SPECIFICATIONS
Description
Battery
Battery Charger