LED INDICATOR
GREEN
Steady Light
No Light
Steady Light
No Light
CHARGING BATTERY PACK INSTRUCTIONS
Before attempting to charge the tool, read all of the safety instructions.
1. Check the mains voltage. Make sure the voltage of the power source is the same
as the voltage specified on the rating-plate of the charger unit.
2. Plug your mains plug into the power source. Green LED indicator will show a
steady light for standing by.
3. Insert battery pack into battery compartment (3) of the charger. Only the Red LED
indicator will show a steady light. That indicates that the battery pack is being
charged automatically.
4. When the battery pack is fully charged, only the Green LED indicator will show a
steady light intelligently.
5. Unplug the battery pack and the charger in turn (unless you would like to charge
another battery pack.)
NOTE
The battery pack was discharged after its manufacture. Therefore, it will require 5-10
charges / discharges before it reaches full capacity.
CAUTION
Longest life and best performance can be obtained if the battery pack is charged
when the surrounding air temperature is between 65°F (18°C) and 75°F (24°C).
DO NOT charge battery pack in an air temperature below 40°F (4.5°C), or above
105°F (40.5°C). This is important and will prevent serious damage to battery pack.
The charger was designed to fast charge battery pack between 32°F (0°C) and
113°F (45°C). If the battery pack just inserted is too cold or too hot, the charger will
not charge it and only the green LED indicator and the red LED indicator will blink
alternatively and continuously.
temperature range, the fast charging procedure will be started automatically.
1English1
CHARGER LIGHT INDICATOR
RED
No Light
Steady Light
Charging
No Light
Charging is complete
Blinking Light
Damaged or faulty battery pack
IMPORTANT CHARGING NOTES
After the battery pack temperature fit standard
English
SITUATION
Standing by
-7