Descargar Imprimir esta página

Gallagher M950 Manual De Instrucciones página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
Gallagher 3E4449 M950 M1400 Energizer User Manual
To Earth System
Step 3. Connect the fence
a)
Connect the energizer's red output ( ) terminal to the fence using
Underground Cable (G627). Remove 5cm (2") of plas c coa ng from one end
of the cable. Unscrew the red (FENCE) terminal and insert the wire through the
terminal slot. Screw the terminal closed, ensuring the wire is fi rmly clamped.
b)
A ach the other end of the cable to the fence using a Joint Clamp (G603).
For instruc ons on fence installa on see the Gallagher Power Fence™ Manual or go
to www.gallagher.com
Step 4. Turn the Energizer On
a)
Plug the energizer into a power outlet and switch ON.
b)
LED lndicators on the front of the energizer light up.
Permanent Fence
1
8
7
2
1
Energizer
2
Earth stake
3
Strain insulator
4
Post insulator
GREEN
3
9
5
Wire ghtener
6
Warning sign
7
Earth (Green)
8
Live (Red)
RED
To Fence
5
4
12
9
10
11
12
11
6
10
Cut out switch
Joint clamps
Strain post
Line post
7

Publicidad