Descargar Imprimir esta página

Homelite UT80522 Manual Del Operador página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

It is important to store this product in a frost-free area. Always
empty water from all hoses, the pump, and the detergent
bucket before storing.
NOTE: Use of a fuel stabilizer and pump saver will give you
better performance and increase the life of the machine.
Discharge Fuel:
Drain the fuel tank completely. Stored gas can go stale in
30 days.
Engine Lubricant:
Drain the lubricant and replace with fresh, clean lubricant.
Spark Plug:
 Disconnect spark plug wire and remove the spark plug.
Pour about a teaspoon of clean, air-cooled, four-cycle
lubricant through the spark plug hole into the combustion
chamber.
 Leaving the spark plug out, pull the starter cord two or
three times to coat the inside of the cylinder wall.
 Inspect the spark plug and clean or replace, as neces-
sary.
 Reinstall the spark plug, but leave the spark plug wire
disconnected.
Air Filter:
Clean the air filter.
Recoil Starter Rope:
Extend the recoil starter rope to check its condition. If the
rope is frayed, have it replaced immediately by an authorized
service center.
PERIODIC MAINTENANCE SCHEDULE TABLE
Maintenance Items
Clean engine & check bolts & nuts
Check engine oil
Change engine oil*
Clean spark plug
Clean air cleaner
Replace air cleaner element
Clean & adjust spark plug & electrodes
Replace spark plug
Remove carbon from cylinder head**
Check & adjust valve clearance**
* Initial oil change should be performed after the first 20 hours of operation. Do not pour old oil down sewage drains,
into garden soil, or into open streams. Your local zoning or environmental regulations will give you more detailed
instruction on proper disposal.
** Have performed by your nearest service center
MAINTENANCE
Hoses and Pump:
Flush the injection hose with clean water for 1-2 minutes.
Remove all hoses. Empty the pump by pulling on the recoil
starter about 6 times. This should remove most of the liquid
from the pump.
For winterizing and long-term storage:
 Disconnect the water connection, if necessary.
 Disconnect the spark plug wire from the engine.
 Pull recoil rope and jump engine several times to eliminate
any water remaining in the pump.
 Coil the hoses and place in the hook-and loop strap on the
unit's handle. Do not allow the hose to become kinked.
 Store the unit and accessories in an area that does not
reach freezing temperatures. Do not store near furnace
or other sources of heat that could dry out the pump
seals.
CAUTION:
The use of a pump protector is recommended to prevent
cold weather damage during storage over the winter
months.
PREPARING FOR USE AFTER STORAGE
 Pull the recoil starter grip three or four times to clean
lubricant from the combustion chamber.
 Remove spark plug from the cylinder. Wipe lubricant from
the spark plug and return it to the cylinder.
 Reconnect the spark plug wire.
 Refuel the machine as described earlier in the operator's
manual.
Each
Every
use
8 hrs.
X
X
X
X
Page 14 — English
Every
Every
Every
20 hrs.
50 hrs.
100 hrs.
X
X
X
Every
300 hrs.
X
X
X
X
X

Publicidad

loading

Este manual también es adecuado para:

Ut80953