INSTALLATION INSTRUCTIONS
E-WFT05B Series
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou
votre code électrique local. Si vous n'êtes pas familier
avec ces codes et ces exigences, veuillez contacter un
électricien qualifié.
3. Suitable for wet locations.
Convient aux emplacements mouilles
4.
Wall mount only.
Installation murale seulement.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
MOUNTING
NOTE: To insure proper installation and service, the fixture should
be mounted with the lens angled toward the ground. Do not
recess. Also make sure fixture is weatherproof by sealing all gaps
and holes with weatherproof silicone sealant.
1.
Open the lens by releasing clips on the top edge of the housing.
2.
Remove the reflector by removing the two reflector retaining
screws.
NOTE: Do NOT touch LED array during installation.
3.
Locate and remove desired conduit plug on the back or sides of
fixture housing.
following:
.
www.e-conolight.com
Document:
LPN00462X0001A1_A
Created By:
TMT
4.
Pull the supply leads through the conduit opening and mount the
fixture to the wall by drilling through the housing approximately 1"
(25mm) diagonally from each corner at the back of the fixture and
securing it to the mounting surface. (Mounting hardware provided
by customer)
5.
All unused holes must be plugged. Apply waterproof silicone to all
mounting holes to ensure a tight seal.
6.
Complete the wiring to the power source and ground (refer to
wiring instructions).
7.
Replace the reflector removed in Step 2. Be careful to not pinch
any wires.
8.
Close lens and fasten retention clips.
ELECTRICAL CONNECTIONS
Fixture is equipped with universal volt driver 120-277V
(ie. 120V, 208V, 240V or 277V)
PHASE TO NEUTRAL WIRING 120/277V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply common to fixture neutral (white) lead.
3. Connect supply Vin to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
PHASE TO PHASE WIRING 208/240V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply L1 (Hot) to fixture neutral (white) lead.
3. Connect supply L2 (Hot) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
CAUTION: Changes or modifications not expressly approved could
void your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Changes or modifications not expressly approved could void your
authority to use this equipment.
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
CAN ICES-005 (B)/NMB-005 (B)
|
888.243.9445
|
FAX: 262.504.5409
Date
ECO#
FCC NOTICE Class B
5-17-2019
010608