Descargar Imprimir esta página

Everbilt EFLS15CI-HD Manual De Instrucciones página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

Pre-installation
BEFORE YOU INSTALL THIS PUMP
WARNING: Risk of explosion. Do not ground to a gas supply line. The pump body may explode if used as a booster pump or other than a
lawn sprinkling application.
CAUTION: Risk of burns. Do not touch an operating motor. Motors are designed to operate at high temperatures. It is protected from heat
damage during operation by an automatic internal cutoff switch. To avoid burns when servicing the pump, allow it to cool for 20 minutes after
shut down before handling.
The pump's water suction inlet must not be more than 20 ft. above the water level.
Long runs and many fittings increase friction and reduce water flow to the pump. Locate the pump as close to the water source as
possible. Use as few elbows and fittings as possible. Ensure the suction line is straight and angles up toward the pump.
Ensure the well and pipe are clear of sand, dirt, and scale. Foreign matter will plug the pump and void the warranty. Use new pipe
for best results.
Protect the pump and all piping from freezing.
Freezing will split pipe, damage the pump and void the warranty. Check locally for frost protection requirements. The pump cannot
be installed below the frost line and the pump must be insulated.
Foot or check valves (not included) must be installed in the suction pipe to optimize pump suction.
Ensure all pipes and valves are clean and in good shape.
Ensure there are no air pockets in the suction pipe.
Ensure there are no leaks in the suction pipe. Use Teflon tape or other approved sealants to seal pipe joints.
Unions installed near the pump and well will aid in servicing. Leave room to use wrenches.
PERFORMANCE DATA
SKU
HP
1001
092
245
1-1/2
MATERIALS REQUIRED (NOT INCLUDED)
Before using this pump, ensure you have the appropriate items based on the installation technique from the following pages.
1-1/2 in.
Suction/Discharge
pipe
1-1/2 in.
Union
Pressure gauge
IMPORTANT: Do not use pipe or fittings on suction side of pump less than 2 in.! This will restrict suction and reduce priming ability and
performance.
DISCHARGE PRESSURE (PSI)
DISTANCE OF PUMP
10
ABOVE WATER
GALLONS PER MINUTE
5 ft.
60
10 ft.
53
15 ft.
47
20 ft.
41
Thread sealant
tape
1-1/2 in. Gate valve
1-1/2 in. NPT
Foot valve with strainer
20
56
50
44
38
1-1/2 in. Check valve
1-1/2 in.
Priming tee
Pressure relief valve
(recommended)
4
30
40
51
37
46
32
41
25
34
22
1-1/2 in. NPT
(or 2 in. NPT with
reducer) strainer
basket with
1/8 in. holes
1-1/2 in. Elbow

Publicidad

loading

Este manual también es adecuado para:

1001 092 245