d. Entry Delay Time
The system has a factory entry delay of 20 seconds.
1. Enter the access code and press PROG four times. ENTRY will now flash on the LCD.
2. Press ARM/DISARM to confirm the selection.
3. Use UP or DOWN to select the entry delay (0, 5, 10 or 20 seconds). Press ARM/DISARM to confirm.
4. Press PROG twice to exit.
e. System Time Setting
1. Enter the access code and press PROG five times.
2. Press ARM/DISARM to confirm your selection.
3. The date will now appear on the LCD in a YY/MM/DD format followed by the time. Flashing numbers can be
modified using UP or DOWN. Press ARM/DISARM to confirm your selection.
4. When finished, press PROG once to exit.
6. Testing the Range of the Wireless Sensor
After selecting a mounting location, press HOME and wait 60 seconds before triggering the sensor. The main unit
should emit a chime and the LCD should display the sensor zone number. Press HOME again to exit the mode.
7. Operation of the Main Unit
a. Arming the System
1. Enter the access code and press ARM/DISARM.
2. You will hear three short beeps and the ARM icon will appear on the LCD.
3. To arm the system, hold ARM pressed on the remote unit for 2 seconds.
4. You will hear another beep after 60 seconds. The alarm is now armed.
5. The main unit will detect now the sensor status (closed or open). The alarm will be activated when the sensor
is still open after 5 seconds.
b. Alarm
1. When armed, the main unit will display a TRIGGER icon and the zone number when a signal has been
intercepted inside the protection zone. A siren will sound for 30 seconds after the set entry delay time has
elapsed.
2. Note that the siren will only sound when activated (see "5.c. Siren ON/OFF").
c. Disarming the System
1. Enter the access code and press ARM/DISARM.
2. You will hear a beep. The ARM icon will disappear from the main unit LCD confirming that the system has
been disarmed.
3. You can also press and hold DISARM for 2 seconds on the remote control.
d. The Panic Button
1. Press the PANIC button on the main unit or hold the PANIC button pressed for 2 seconds on the remote
control. The alarm will sound instantly.
2. Enter the access code and press ARM/DISARM on the main unit to stop the siren. You can also hold DIASRM
pressed for 2 seconds on the remote control.
HAM1000WS_v3
will now flash on the LCD.
5
VELLEMAN