• By turning anti-clockwise, the water flow will be
reduced.
Finish operation
After use allow the pump to run using clean water
for 2 - 3 minutes in order to remove residues and
particles that may have accumulated in the pump
and outlet hose.
5. MAINTENANCE
Before cleaning and maintenance, always
switch off the machine and remove the
mains plug from the mains.
During maintenance or cleaning never rest
the appliance on the impeller.
Clean the machine casings regularly with a soft
cloth, preferably after each use. Remove very per-
sistent dirt using a soft cloth moistened with soap-
suds. Do not use any solvents such as gasoline,
alcohol, ammonia, etc. Chemicals such as these
will damage the synthetic components.
There are no user serviceable parts in this ap-
pliance. If the appliance appears to be blocked,
switch off the power at the mains, remove the plug
from the socket and check the appliance for block-
age (see 'clean the filter' and 'blockages').
Clean the filter (A,E)
Clean the filter (15) at regular intervals, and check it
for damage. Otherwise, its function can be impaired.
1. Unscrew the filter cover (14) by turning counter
clockwise and remove filter (15) as shown in Fig. E.
2. Use a mild soap and water solution to clean the
filter and afterwards rinse with clean water.
3. Re-install the filter (15) and the filter cover (14).
Screw the filter cover (14) by turning clockwise.
Always flush through with clean water after
every use.
Blockages
If you suspect the pump has become blocked,
switch off the power at the mains socket remove the
plug and examine the turbine. The turbine can be
accessed by removing the securing screws in the
base (4).
8
STORAGE AND FROST POTECTION
The submersible pump and accessories that are not
completely drained can be destroyed by frost. Com-
pletely drain the submersible pump and accessories
and protect them against frost.
Keep this appliance in well-ventilated dry premises
with temperature not going below +5°C.
When not in use, keep this appliance stored in a safe
place out of reach of children.
TROUBLE SHOOTING GUIDE
Problem
Cause
Pump does not
No mains supply.
start.
Float switch
restricted.
Pump is active
Impeller clogged. Disconnect pump
but no water is
being delivered.
Pump will not
Float switch
switch off.
restricted.
Pump will not
Thermal overload
start or stops
safety switch has
during use.
activated.
Pump switched
off after short
operating
Power has
periods.
tripped.
Filter / turbine
clogged.
Floater restricted. Bring floater to
Water too hot.
Remedy
Check mains supply.
Bring floater to
a higher position.
from the power
supply and clean the
filter / impeller
(see 'MAINTENANCE').
Bring float switch to
a lower position.
Disconnect from the
power supply, leave
for 2 minutes and
clear the turbine (see
'MAINTENANCE').
Check fuses and
electrical connec-
tions.
Disconnect pump
from the power
supply and clean the
filter / turbine
(see 'MAINTENANCE').
a higher position.
Ensure that the wa-
ter temperature has
not exceeded the
maximum of 35°C.