GB
STOP FUNCTION
If the transmitters are memorised only on COSTA1 ("EDGE1") it
will be possible to use the COSTA 2 ("EDGE 2") output with a STOP
function.
Set dip-switch 3 to ON (1 in Fig. 7) and connect the receiver's
COSTA 2 ("EDGE 2") output to the gate control unit's STOP input.
In the event of a malfunction of any kind on the SRC system, this
output (the contact must be set to N.C.) will perform a STOP to
block all the functions.
BATTERIES
The transmitter has 2 type AAA alkaline batteries.
These batteries have a lifetime of approximately 2 years. When it is
nearly time to replace them, the transmitter will send a signal to
the receiver that makes the buzzer sound approximately every 4
seconds.
If there is more than one transmitter, operate the various edges
manually: the receiver's buzzer will emit a sound when the
transmitter with the low batteries is activated. Replace the
batteries as soon as possible. Under no circumstances use
rechargeable or Zinc-Carbon batteries.
OUTPUT TESTING
On the receiver there are two test inputs (4 in Fig. 7), one for each
output.
Applying 24V to TEST1 activates output COSTA1 ("EDGE1");
applying 24V to TEST2 activates output COSTA2 "EDGE2".
This control function can be used only on specially designed gate
control units.
34