I N S T R U C T I O N M A N U A L
DF16 EXTRACTOR
DF16E350
KIT CONTENT
nd
Extractor
2
thermal
Power
UE
UK
US
Adaptor
Modul
sensor
Supply
Adaptor
Adaptor
Adaptor

Publicidad

loading

Resumen de contenidos para Secret Jardin DF16E350

  • Página 1 I N S T R U C T I O N M A N U A L DF16 EXTRACTOR DF16E350 KIT CONTENT Extractor thermal Power Adaptor Modul sensor Supply Adaptor Adaptor Adaptor...
  • Página 2 SUMMARY 1. Product Setup ........p. 4 2. Intake Extractor ........ p. 6 2. User Interface ........p. 6 3. Thermal Sensor ......... p. 8 4. Technical data ........p. 3 5. Safety guideline ......p. 13 6. CE Conformity ......... p. 16...
  • Página 3 TECHNICAL DATA ADVISED VALUE GROW ROOM TENT VOL. Advised MAX EXT. Advised FILTERS* DS60 60x60x160cm 0.6m3 150m3/h DF16F150 90x90x180cm DS90 1.4m3 250m3/h DF16F250 DS120 120x120x200cm 2.9m3 350m3/h DF16F350 GROW ROOM TENT VOL. Advised MAX EXT. Advised FILTERS* DS60 2x2x5¼ft 20ft3 90cfm DF16F150 DS90...
  • Página 4 PRODUCT SET UP EXTRACTOR INSIDE EXTRACTOR OUTSIDE INTAKE INSIDE INTAKE OUTSIDE 4 POSITIONS Extraction / Intake Inside / Outside...
  • Página 5 PRODUCT SET UP /!\ For ease of installation, assemble your extractor to the Ducting Flange DF16 before connecting it to its 24volt power supply. /!\ Pour faciliter son installation, assembler votre extracteur à la Ducting Flange DF16 avant de le connecter à son alimentation 24volt. /!\ Para facilitar la instalación, ensamble su extractor a la Ducting Flange DF16 antes de conectarlo a su fuente de alimentación de 24 voltios.
  • Página 6 USER INTERFACE EXAMPLE Grow Space : DS120 EXT. MAX : 350m3/h - 210cfm TEMP° : 27°C - 80°F EXT. MIN : 20% > < 27°C/80°F 27°C/80°F T° T° (TARGET TEMPERATURE) (TARGET TEMPERATURE) 350m3/h 70m3/h 210cfm 41cfm (EXT. MAX) (EXT. MIN 20%)
  • Página 7 USER INTERFACE 1. Choose your target temperature (TEMP°) The extractor will regulate the temperature with a delta of +/- 2°C (4°F) 2. Determine the minimum extractor speed (EXT. MIN) In order to continue to renew the air in case of low temperature. 3.
  • Página 8 THERMAL SENSOR Thermal sensor integrated & deported When the 2 nd thermal sensor is connected, the integrated sensor will be OFF. If you use the integrated thermal sensor, the extractor will run at 5% minimum speed. Capteur thermique intégré & déporté Lorsque le deuxième capteur thermique est connecté, le capteur intégré...
  • Página 9 THERMAL SENSOR CONFIGURATION 1 CONFIGURATION 2 2 nd THERMAL SENSOR INTEGRATED SENSOR...
  • Página 10 DF16E350 COMPATIBILITY COMBINE TWO EXTRACTORS If you want to combine two extractors and keep your LIGHT BAFFLE* (intake) : add an « intractor » to increase the flow. Attach the T° probes together (Enter the probe with a CF7D), add 2°C more in intraction and put the same values for «...
  • Página 11 « Ext. Max. » & « Ext. Min » su entrambi gli estrattori. * Se rimuovi il tuo LIGHT BAFFLE pensa a ridurre la velocità massima del tuo intrattore. + 1x INTAKE +75% VENTILATION CONFIG. 1x DS120 (TENT) 2x DF16E350 (EXTRACTOR) 1x DF16F350 (FILTER) 1x CF7D (CABLE SOCK)
  • Página 12 M. Jacques Bordes Supplier’s Declaration of conformity 47 CFR § 2.1077 Compliance Information Unique Identifier Responsible Party – U.S. Contact Information Trade Name: Secret Jardin DL WHOLESALE Inc Model No.: DF16E350 7041 Las Positas Rd. Suite A Livermore CA94551 UNITED STATES...
  • Página 13 I N S T R U C T I O N M A N U A L DF16 EXTRACTOR DF16E150 KIT CONTENT Extractor thermal Power Adaptor Module sensor Supply Adaptor Adaptor Adaptor...
  • Página 14 SUMMARY 1. Technical data ........p. 3 2. Product Setup ........p. 4 3. Intake Extractor ........ p. 6 4. User Interface ........p. 6 5. Thermal Sensor ......... p. 8 6. Safety guideline ......p. 13 7. CE Conformity ......... p. 16...
  • Página 15 TECHNICAL DATA ADVISED VALUE GROW ROOM TENT VOL. Advised MAX EXT. Advised FILTERS* DP60 60x40x60cm 0.1m3 50m3/h DF16F100 DP90 90x60x98cm 0.5m3 100m3/h DF16F100 DS60 60x60x158cm 0.6m3 150m3/h DF16F150 GROW ROOM TENT VOL. Advised MAX EXT. Advised FILTERS* DP60 2x2x5¼ft 5ft3 30cfm DF16F100 DP90...
  • Página 16 PRODUCT SET UP EXTRACTOR + DF16F100 EXTRACTOR INSIDE + DF16F150 EXTRACTOR OUTSIDE + DF16F150 INTAKE INSIDE INTAKE OUTSIDE 4 POSITIONS Extraction / Intake Inside / Outside...
  • Página 17 PRODUCT SET UP /!\ For ease of installation, assemble your extractor to the Ducting Flange DF16 before connecting it to its 24volt power supply. /!\ Pour faciliter son installation, assembler votre extracteur à la Ducting Flange DF16 avant de le connecter à son alimentation 24volt. /!\ Para facilitar la instalación, ensamble su extractor a la Ducting Flange DF16 antes de conectarlo a su fuente de alimentación de 24 voltios.
  • Página 18 USER INTERFACE EXAMPLE Grow Space : DS60 EXT. MAX : 150m3/h - 90cfm TEMP° : 27°C - 80°F EXT. MIN : 20% > < T° 27°C/80°F T° 27°C/80°F (TARGET TEMPERATURE) (TARGET TEMPERATURE) 150m3/h 30m3/h 90cfm 18cfm (EXT. MAX) (EXT. MIN 20%)
  • Página 19 USER INTERFACE 1. Choose your target temperature (TEMP°) The extractor will regulate the temperature with a delta of +/- 2°C (4°F) 2. Determine the minimum extractor speed (EXT. MIN) In order to continue to renew the air in case of low temperature. 3.
  • Página 20 THERMAL SENSOR Thermal sensor integrated & deported When the 2 nd thermal sensor is connected, the integrated sensor will be OFF. If you use the integrated thermal sensor, the extractor will run at 5% minimum speed. Capteur thermique intégré & déporté Lorsque le deuxième capteur thermique est connecté, le capteur intégré...
  • Página 21 THERMAL SENSOR CONFIGURATION 1 CONFIGURATION 2 2 nd THERMAL SENSOR INTEGRATED SENSOR...
  • Página 22 DF16E150 COMPATIBILITY EXTRACTOR WITH DF16 EXTRACTOR WITHOUT DF16 EXTRACTOR + DF16F100 COMBINE TWO EXTRACTORS If you want to combine two extractors and keep your LIGHT BAFFLE* (intake) : add an « intractor » to increase the flow. Attach the T° probes together (Enter the probe with a CF7D), add 2°C more in intraction and put the same values for «...
  • Página 23 « Ext. Max. » & « Ext. Min » su entrambi gli estrattori. * Se rimuovi il tuo LIGHT BAFFLE pensa a ridurre la velocità massima del tuo intrattore. + 1x INTAKE +50% VENTILATION CONFIG. 1x DS120 (TENT) 1x DF16E150 (EXTRACTOR) 1x DF16E350 (EXTRACTOR) 1x DF16F350 (FILTER) 1x CF7D (CABLE SOCK)
  • Página 24 DF16 e un filtro in modo che l’elica non sia accessibile. Make sure that your transformer is in a dry environment and protected from any water splashes (outside a Secret Jardin tent). Assurez vous que votre transformateur soit dans un environnement sec et à l’abri de toute pro- jection d’eau (À...
  • Página 25 SAFETY Thank you for choosing to purchase a Secret Jardin product. Before using your device, please read this manual carefully. • Safety Guidelines Read the rating label (stuck on each device) make sure that the voltage conforms to your electricity supply •...
  • Página 26 Vielen Dank, dass Sie sich für den Kauf eines Secret Jardin-Produktes entschieden haben. Bitte lesen Sie dieses Handbuch sorgfältig durch, bevor Sie Ihr Gerät benutzen.
  • Página 27 SAFETY Bedankt voor uw keuze om een Secret Jardin product te kopen. Lees deze handleiding zorgvuldig door voordat u het apparaat in gebruik neemt. Veiligheidsinstructies Lees het evaluatie-etiket (dat op elk apparaat is aangebracht) en zorg ervoor dat de spanning overeenkomt met uw stroomvoorziening •...
  • Página 28 M. Jacques Bordes Supplier’s Declaration of conformity 47 CFR § 2.1077 Compliance Information Unique Identifier Responsible Party – U.S. Contact Information Trade Name: Secret Jardin DL WHOLESALE Inc Model No.: DF16E150 7041 Las Positas Rd. Suite A Livermore CA94551 UNITED STATES...