Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Sound-control:
Dimensions (LxWxH):
Weight:
Maximum ambient temperature T
Maximum housing temperature T
Min.distance from flammable surfaces:
Min.distance to lighted object:
Fuse:
Accessory:
OSRAM 64515 230V/300W GX-6.35 15h
GE A1/249 240V/300W G-6.35 50h
OMNILUX 230V/300W GX-6.35 75h 3200K
OSRAM 64516 240V/300W GX-6.35 75h
Please note: Every information is subject to change without prior notice. 26.08.2008 ©
230 V AC, 50 Hz ~
610 W
via built-in microphone
295 x 270 x 185 mm
3 kg
:
45° C
a
(steady state):
180° C
B
0.5 m
0.5 m
F 3.15 A, 250 V
No. 88296010
No. 88296100
No. 88296105
No. 88296110
19/35
00026416.DOC, Version 2.0