Descargar Imprimir esta página

Comfort Glow ECH270 Manual Del Propietário página 19

Publicidad

Idiomas disponibles

Idiomas disponibles

SPECIFICATIONS:
1. Technology:
a. Convection
a. Type (*Specify type of tube if applicable)
b. Number
2. Input Voltage/Hz
a. 120V, 60Hz
3. Number of settings
4. BTU/hr rating at each setting.
5. Power consumption at each setting. (watts)
6. Maximum amperage draw at each setting
7. Material rating. What is the maximum safe temperature of the
components inside the heater?
a. wire
b. Non-metal material inside the heater.
c. The housing material
d. Control board and its components
8. Over Heat Protection (OHP) switch (Manual or Automatic reset)
a. Maximum operation temperature
b. Over Heat Protection Switch operating temperature and
tolerance range
i. Shut-off Temeprature and tolerance range
ii. Re-set Temperature and tolerance range
iii. Does the fan stop after OHP switch is activated?
9. Normal temperature control (Thermostat Control)
a. Shut-off Temperature and tolerance range
b. Re-start Temperature and tolerance range
c. Does the fan stop after maximum normal operating
temperature switch is activated?
10. Tip-over protection (Tolerance range and directions)
11. Maximum inrush Amperage
12. Power Cord:
a. Length
b. Type
c. Size
d. NEMA Plug configuration
13. Product Demesions (in) (H x W x D)
14. Product Weight: (lbs)
Yes
coil wire
1
Yes
2
5118BTU/hr
1500W
12.5A
Min. 176⁰F, Max. 392⁰F
Heating Shrinkable Tube: 257⁰F
230⁰F
194⁰F-257⁰F
Manual reset
293⁰F
293 +/-5⁰F
275 +/-5⁰F
N/A
194 +/-5⁰F
185 +/-5⁰F
N/A
60degree +/-5degree
12.5A
5.9'
HPN-R
16AWG x 2C
1-15P
28.14*5.11*8.66
4.05lbs
~ 19 ~

Publicidad

loading