▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ FRY TOP (GAS SUPPLY)
– The faucet (not supplied with the appliance) must be installed in a visible and accessible
position in order to easily identify its operating status (open or closed).
GAS SUPPLY TRANSFORMATION
The appliance is marketed with indications of the gas mains used by the manufacturer
for inspections.
If the gas mains do not correspond to the one used for inspection, before connecting
the gas mains, the installation technician must "transform" the appliance and indicate
the type of gas in use on the plate.
Important
After "transforming" the appliance to the gas mains in use, make sure there are no
gas leaks or operating defects, test the appliance and indicate the type of gas in use
on the identification plate.
To "transform" and adapt the appliance to the gas mains in use, close the gas supply
faucet and perform the listed operations.
– Burner nozzle replacement.
– Heat power adjustment to minimum
burner nozzle replacement
1 - Remove bottom of the appliance.
2 - Unscrew the nozzle and replace it with the one suited for the gas used.
Table 4: nozzle dimensions
Supply gas type
G20 (20 mbar)
G30 (28-30 mbar)
G30 (50 mbar)
FRY1/LM-LMC - FRY1/RM-RMC
Burner nozzle diameter
1,35 mm
0,93 mm
0,77 mm
- 19 -
FRY2/LM-LMC - FRY2/LRM-LRMC
Burner nozzle diameter
2 x 1,35 mm
2 x 0,93 mm
2 x 0,77 mm