▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ FRY TOP (GAS SUPPLY)
Heat power adjustment to minimum
METHANE GAS powered appliance
1 - Turn on the appliance and run it at
maximum power for about 10 minutes.
2 - Rotate the burner control knob to the
minimum power position and pull it out.
3 - Turn the minimum adjustment screw
(D) clockwise or counter-clockwise to
achieve a stable flame.
4 - Rotate the burner control knob to turn it
off.
5 - Repeat minimum adjustment if the ap-
pliance is equipped with another burner.
6 - Seal the adjustment screw with paint and repeat the operation on the other burner (if
installed).
EN
7 - Reassemble the burner knob and the other burner knob (if installed).
LIQUID PROPANE GAS powered appliance (LPG)
1 - Remove the knob.
2 - Fully tighten the minimum adjustment screw (D).
3 - Pull out the knob and tighten the second burner screw (if installed).
4 - Turn on the appliance and make sure the flame is stable.
5 - Turn off the appliance. Seal the adjustment screw with paint and repeat the operation
on the other burner (if installed).
6 - Reassemble the burner knob and the other burner knob (if installed).
EXTRAORDINARY MAINTENANCE
– All extraordinary maintenance such as broken or worn component replacement must be
performed by authorised personnel with specific technical skills and special abilities in
the specific sector.
– After maintenance (routine and extraordinary), always make sure that operations were
correctly performed before running the appliance.
D
- 20 -
English language