CAUTIONS
Do not install the unit in a place where a flammable gas leaks.
• If gas leaks and accumulates in the area surrounding the unit, it could cause an explosion.
Perform the drainage/piping work according to the installation instruction.
• If there is a defect in the drainage/piping work, water could leak from the unit and household
goods could get wet and be damaged.
INSTALLATION OF INDOOR AND OUTDOOR UNITS
Read completely, then follow step by step.
More than 12 cm.
Indoor unit
Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles in front or around the unit.
Make sure that condensation drainage can be conveniently routed away continuously going down-
wards.
Do not install near a doorway.
Ensure that the space on the left and right of the unit is more than 12cm.
Use a stud finder to locate studs to prevent unnecessary damage to the wall.
The top of the indoor unit should be installed on the wall at a height of 2.3 metres or more from the floor.
The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling.
Any variations in pipe length will/may require adjustment to refrigerant charge.
LEFT
More than 30 cm.
FRONT
More than 200 cm.
10:55
Pagina 61
More than 15 cm.
2.3 m or more
More than 60 cm.
More than 30 cm.
More than 12 cm.
BACK
RIGHT
More than 60 cm.
4
61