• CONTROL PANEL R7I: It controls all equipment functions. It can be
used for roof air coolers in two voltages: 12V and 24V. It doesn't have
a fixed useful life since this depends on the handling and periodical
revisions. This product is equipped with an internal safety circuit against
fan and pumps short-circuits. In case your roof air cooler stops working,
always check the fan and pumps first, since the defect could not be on
the control panel. The control panel may have turned off, protecting
itself against some other electrical defects. Check also the general fuse
in the battery.
Note: For this roof air cooler, only use control panel R7i. Other
versions are not suitable.
R7I MODEL
4. Fault Codes
R7i Control Panel
OPERATIONAL FAULTS
Failure beep / key leds / "água/water", "abastecer/fill
up" and "sleep" symbols flashing
Failure beep / key leds flashing
Failure beep / "água/water" symbol flashing
Failure beep / "abastecer/fill up" symbol flashing
CAUSE
Short-circuit fan
Fan overload
Failed injection pump (located inside
the tank)
Failed return pump (located at the base)
21