6159945800_10
Series: B
MAINTENANCE INSTRUCTIONS
The use of spare parts other than those
originally supplied by the manufacturer
may result in a drop in performance or
in increased maintenance and level of
vibration and in the full cancellation of the
manufacturer's liability.
To obtain maximum efficiency from the
pneumatic tool, preserve its features
and avoid repeated repairs, a routine
inspection and repair programme
are recommended at least every 500
hours, the intervals between the various
inspections depending on the amount of
exertion on the power tool.
When disposing of components,
lubricants, etc... ensure that the relevant
safety procedures are carried out.
This tool is fitted with blades which can
operate without lubricated air. However,
a small amount of oil allows the tool to
provide full power and lengthens its life.
The use of dry air with no trace of oil may
reduce the life of blades.
DISASSEMBly AND REASSEMBly
INSTRUCTIONS
● Disconnect the machine from the compressed
air supply . Remove all accessories.
● Before disassembling the machine,
decompress the air from the oil tank by
loosening and retightening the screw (9).
● At each disassembly of the governor, clean
the spring housing, check the condition of the
spring and re-lubricate it carefully.
The governor has a calibrated spring which can
only be replaced by an original spare part.
● At each disassembly of the bevel gear,
change the Nylstop nut (605.57).
● Before removing the turbine assembly from
the motor housing, do not forget to remove
the decompression fitting (746.52).
● When re-assembling, always position the
cylinder exhaust on the opposite side of the
turbine housing.
10 / 28
English
05/2013