LUBRICATION
All models may operate without airline lubrication. However, operating the tool without airline lubrication may reduce tool performance and vane life.
If an airline lubrication is not used, it is recommended that the tool be oiled daily before use to improve performance. Add 2-4 drops of air motor oil and run the
tool for 10-20 seconds to distribute oil through the tool.
For maximum performance and tool life, an air line lubricator, set to deliver 2 drops per minute, is recommended. SIOUX No. 288 Air Motor Oil is
recommended.
Do not over lubricate because excess oil may contaminate the surface being polished.
For Angle Head
Lubricate the angle head assembly with 2 shots of SIOUX #1232 grease every 8 working hours.
MAINTENANCE
Water, dust and other airline contaminants can cause rust and vane sticking. For long periods between tool use, flush the tool with a few drops of oil and run
for 10 seconds. This will help remove contaminants and reduce the formation of rust.
OPERATION
The tool is equipped with a locking type lever in order to prevent accidental start-up.
Speed of the tool may be adjusted by turning the regulator, which is located opposite the throttle lever.
The angle head can be repositioned by loosening the retaining collar and positioning the angle head in the desired position and retighten the retaining collar.
Catalog
Number
SAP10A457
SAP10A327
SAP10S227
SAP10S327
SSP10S605-11
Form ZCE845
NOISE AND VIBRATION READINGS
Noise* (Tested in accordance with ISO Standard 15744)
*Sound Pressure
*Sound Power
(dBA)
(dBA)
TBD
TBD
TBD
TBD
82.4
94.1
TBD
TBD
TBD
TBD
Uncertainty (dBA)
TBD
TBD
3.0
TBD
TBD
3
Vibration* (Tested in accordance with
ISO Standard 28927-3:2009)
*Vibration m/s
Uncertainty m/s
2
TBD
TBD
TBD
TBD
1.55
0.14
TBD
TBD
TBD
TBD
2021June9/E
Date
2