Vacuum power regulator (2)
Low vacuum power:
Medium vacuum power:
High vacuum power:
Cable winding device
Pull out the cable up to the maximum length indicated with the
yellow mark. Never pull the cable out up to the red mark as the
cable winding can be damaged. Said damages are not covered
by the warranty.
Winding
Press the carrying handle down with your foot above the symbol
with the plug and guide the cable into the device. Hold the cable
to avoid wrapping.
Nozzle Attachment
Crevice and
For vacuuming upholstery, curtains and
jointed nozzle:
in corners and crevices etc.
„2-in-1" nozzle: When this is folded toge-
ther it can be used as a groove nozzle.
If you would like to use the brush nozzle,
pull the brush section in the direction of
the arrow until it locks in place.
Floor nozzle:
To clean carpets or smooth surfaces.
Smooth
Press down the lever with the brush symbol
fl oors:
with your foot. The brush is now visible.
Carpets: Press the lever In the opposite direction.
The brushes are now retracted.
Releasing the
Pull these off while turning slightly.
nozzles:
Air Slide (1)
Open the air slide on the hose handle in order to regulate the
airfl ow or to clear any particles sticking to the nozzle.
Dust bag replacement display (6)
Hold the hose up into air. If the display is red the bag is full.
Please replace it.
Changing the dust bag
Pull the plug out of the socket.
Open the lid of the dust bag compartment by the handle (7)
(the cover must click into place).
Remove the bag by carefully pulling the clamp towards
the front so that the bag becomes more accessible. Then
remove the dust bag by pulling it upwards.
Insert a new bag. Please ensure that the bag is located
correctly in the guide mechanism. Then reinsert the retainer.
Close the cover so that it snaps into place.
26
05-BS 985 CB 26
For curtains and delicate fabrics
For long-pile velour carpets and
textile fl ooring
For sturdy rugs and fl oors
Filter
Your appliance has two fi lters.
Motor protection fi lter (inlet fi lter)
The inlet fi lter is located in the dust bag compartment. The fi lter
is located vertically in the rear section of the dust housing.
Remove the grille by pulling it upwards and then take out the
motor protection fi lter.
Clean the engine protection fi lter after 10 dust bag changes.
If necessary, the fi lter can also be washed in warm water
without any additives.
Place it back into place only once it is completely dry!
Please push the grille back down into the guide mechanism
so that it is correctly positioned.
Outlet fi lter
The appliance is also equipped with an outlet fi lter. This fi lter is
to be found under the fi lter cover (8).
Open the ventilation grille by
simultaneously pressing the levers
on the bottom edge of the ventilati-
on grille.
Then pull the grille out towards the
front.
Remove the fi lter and clean as
described above.
Please re-insert the fi lter correctly
and close the ventilation grille
(until it clicks in place).
Cleaning and storage
Cleaning
Pull the plug out of the socket before cleaning!
Clean the casing with a dry cloth.
Storage
Let the iron cool down completely.
Wind the cable completely.
If you position the device horizontally: Please insert the hook
of the fl oor nozzle into the parking assistant on the rear of
the device.
If you place the vacuum cleaner in a vertical position: Please
hang the hook of the fl oor nozzle in the parking aid on the
underside of the vacuum.
Troubleshooting
The Device Does Not Work.
Remedy:
Check the connection to the mains.
Check the position of the switch.
The device does not suck up anything.
Possible Cause:
The suction power is set too low.
29.03.2007, 15:13:57 Uhr