Problem
Icemaker is not
Demand exceeds ice storage capacity.
making enough ice.
• The icemaker will produce approximately 70-184 cubes in a 24 hour period.
House water supply is not connected, valve is not turned on fully, or valve is clogged.
• Connect the refrigerator to a cold water supply with adequate pressure and turn the water
Low house water supply pressure.
• The water pressure must be between 20 and 120 psi on models without a water filter and
Reverse osmosis filtration system is used.
• Reverse osmosis filtration systems can reduce the water pressure below the minimum
Tubing connecting refrigerator to house supply valve is kinked.
• The tubing can kink when the refrigerator is moved during installation or cleaning
Doors are opened often or for long periods of time.
• If the doors of the unit are opened often, ambient air will warm the refrigerator which will
Doors are not closed completely.
• If the doors are not properly closed, ice production will be affected. See the "Doors will not
The temperature setting for the freezer is too warm.
• The recommended temperature for the freezer compartment for normal ice production is
shutoff valve fully open. If the problem persists, it may be necessary to contact a plumber.
between 40 and 120 psi on models with a water filter. If the problem persists, it may be
necessary to contact a plumber.
amount and result in icemaker issues. (Refer to the Connecting the Water Line section.)
resulting in reduced water flow. Straighten or repair the water supply line and arrange it to
prevent future kinks.
prevent the unit from maintaining the set temperature. Lowering the refrigerator
temperature can help, as well as not opening the doors as frequently.
close correctly or pop open" section in Parts & Features Troubleshooting for more
information.
0°F. If the freezer temperature is warmer, ice production will be affected.