CVS2
Figure 12 - Wiring Diagram
SW POSITION
SHOWN WITH
DOWNDRAFT IN
LOWERED POSITION
ABBREVIATIONS:
C= COMMON
NO = NORMALLY OPEN
NC = NORMALLY CLOSED
Fig. 12 – Wiring Diagram
UCV2
Figure 12 - Wiring Diagram
SW POSITION
SHOWN WITH
DOWNDRAFT IN LOWERED
POSITION
ABBREVIATIONS:
C= COMMON
NO = NORMALLY OPEN
NC = NORMALLY CLOSED
Fig. 12 – Wiring Diagram
18
All manuals and user guides at all-guides.com
G:
WER UST BE D SC
WAR
G:
WER UST BE D SC
WAR
ECTED BEF RE SERV C G T S A
ECTED BEF RE SERV C G T S A
CA CE
POWER
3 WIRE SINGLE PHASE 60 Hz
L1: 120 V
N: GROUNDED WHITE WIRE
SPEED 1 RED WIRE
SPEED 2 BLUE WIRE
SPEED 3 BROWN WIRE
GND: GROUNDED GREEN WIRE
RATING: 120V-10A
CA CE
POWER
3 WIRE SINGLE PHASE 60 Hz
L1: 120 V
N: GROUNDED WHITE WIRE
SPEED 1 RED WIRE
SPEED 2 BLUE WIRE
SPEED 3 BROWN WIRE
GND: GROUNDED GREEN WIRE
RATING: 120V-10A