Descargar Imprimir esta página

ims PRO IMS 300 TRI Manual De Instrucciones página 17

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
REMOTE CONTROL
The remote control operates in TIG mode and in MMA.
ref. 045699
Connection :
1- Plug the remote control into the connection at the front of the machine (FIG 1 - 4).
2- Press the
button to activate the remote control. The ON LED lights up.
Connection :
The IMS 300/400 is equipped with a female socket for a remote control.
The specific 7-pin plug (option ref. 045699) allows a manual remote control to be connected to it. For the cabling layout, please see the diagram
below.
REMOTE CONTROL TYPE
Manual remote control
Operating :
• Manual remote control (option ref. 045675)
The remote control enables the variation of current from 50% to 100% of the set intensity.
VRD (VOLTAGE REDUCTION DEVICE)
By default (factory setting), the VRD switch is in the ON position. To activate the VRD, in order to lower the no-load voltage of the
generator (< 20 V), the switch on the control board must be toggled to 1 (page 67 - n°14/ page 68 - n°11). The HMI indicator
1
light (FIG 2 - N°3) lights up.
To access the VRD switch (see page 69):
ELECTRIC SHOCKS CAN BE FATAL
- Disconnect the product from the power supply.
- Remove the 9 screws to open the side of the machine.
- Locate the red switch in the centre of the control board.
ADVICE & THERMAL PROTECTION
This device is equipped with a ventilator regulated by the inside temperature. When the machine's thermal protection is activated, it will not deliver
any current. Yellow light (FIG 2 - 2) will turn on until the temperature of the machine has returned to normal.
• Do not block/cover the ventillation holes, ensure free flow of air.
• Whilst in thermal protection mode leave the machine plugged into the mains after welding to allow it to cool.
General observations :
• Always respect the basic rules of welding.
• Always work in an adequately ventillated area.
• Do not work on a damp surface.
300 / 400 TRI
G
F
A
B
E
D
C
External view
Wire description
Common/Earth
C
B
A
Electrical diagram for remote control.
12 V
Cursor
EN
Pin
A
B
C
17

Publicidad

loading

Este manual también es adecuado para:

Ims 400 tri