Descargar Imprimir esta página

Atmor Thermo Pro2 Serie Manual De Instrucciones página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical Specifications by Heater Input
Item #
AT-912-18TP2
AT-912-24TP2
AT-912-29TP2
Power Rates
Item #
AT-912-18TP2
AT-912-24TP2
AT-912-29TP2
Wiring Diagram for 18kW
Wiring Diagram for 24kW, 29kW
10
kW
Max
Required Breaker
Amps
18
75
2 x 40A Double Pole
24
100
3 x 40A Double Pole
29
120.8
3 x 40A Double Pole
240V
18,000 Watts
15,125 Watts
24,000 Watts
20,166 Watts
29,000 Watts
24,368 Watts
40 Amp
40 Amp
Double Pole
Double Pole
L1
L2
L1
L2
Unit Requires 10 AWG ground wire - one for each 240V circuit
2 x 8/2 AWG with Ground
3 x 8/2 AWG with Ground
3 x 8/2 AWG with Ground
220V
208V
13,520 Watts
18,026 Watts
21,782 Watts
40 Amp
40 Amp
Double Pole
Double Pole
L1
L2
L1
L2
8/2 AWG
8/2 AWG
Unit Requires 10 AWG ground wire - one for each 240V circuit
40 Amp
Double Pole
L1 L2
L1
L2
8/2 AWG
8/2 AWG
8/2 AWG
Req. Wire Size
Terminal Block in Unit
L1 L2
L1 L2
Terminal Block in Unit
L1 L2
L1 L2

Publicidad

loading