Water is too
The water flow rate
hot.
through the heater is too
slow.
Temperature setting is too
high
Water Temperature at
faucet is too hot.
Heater shuts
Power outage or faulty
off during use.
wiring.
Water stops
Possible Blockage in water
flowing.
pipes or hoses.
Water
Water pressure has
temperature
dropped below a minimum
varies from hot
level.
to cold during
use.
Increase the flow rate at the water outlet.
Switch to a lower temperature setting.
Check for too little flow, or if the set point temperature is too high.
This could possibly indicate a possible internal part failure. Call us for
technical assistance.
Check the power supply. Check the circuit breakers.
If the problem persists, please call us for further technical assistance.
Make sure the main water line valve is fully open, and there are no
obstructions in the water supply line.
Increase the flow rate from the water supply source.