Technical Information
Model
*Wattage Voltage Amperage Phase
AT-800-35
3.0 kW
AT-800-04
3.8 kW
AT-800-70
7.0 kW
AT-800-08
8.5 kW
AT-800-10
10.5 kW
AT-800-13
13 kW
Minimum water flow to activate unit: 0.5 GPM
Nominal water volume: 2.7G/Min
Working pressure: 0.5 -8 bar (7 -115 psi)
Tested pressure: 16 bar (230 psi)
Water connections: 1/2" NPT
Dimensions (in) (H x W x D): 7.3 x 11.8 x 3.55
Weight (Ib): 3.4
* Wattage based on maximum voltage.
Model Guide - kW Output
Model
AT-800-04
AT-800-70
AT-800-08
AT-800-10
AT-800-13
AT-800-35
110
27
240
16
240
29
240
36
240
44
240
55
240V
220V
3.8 kW
3.2 kW
7.0 kW
5.4 kW
8.5 kW
7.1 kW
10.5 kW
8.8 kW
13.0 kW
10.9 kW
-
-
Circuit breaker
size
1
30
1
20
1
30
1
40
1
50
1
60
110V
-
-
-
-
-
3.0 kW
Required wire
size
10 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
120V
-
-
-
-
-
3.5 kW
2