Fig. 1
Fig. 2
Fig. 3
Fig. 5
Fig. 4
Fig. 6
Fig. 7
To facilitate explanation, the accompanying illustra-
tion has been drawn to show all possible indicators;
in actral operation, however, the display will only
show those indicators appropriate to the current op-
eration.
06B030_9315255044-01_Cover
2
CONTENTS
SAFETY PRECAUTIONS ..................................... En-1
ADJUSTING THE DIRECTION OF
FEATURES AND FUNCTIONS ............................ En-2
AIR CIRCULATION .............................................. En-9
NAME OF PARTS ................................................ En-3
SWING OPERATION ......................................... En-10
PREPARATION .................................................... En-4
MANUAL AUTO OPERATION .......................... En-10
OPERATION ........................................................ En-5
CLEANING AND CARE ...................................... En-11
TIMER OPERATION ............................................ En-7
TROUBLESHOOTING ....................................... En-13
SLEEP TIMER OPERATION ................................. En-8
OPERATING TIPS .............................................. En-14
SAFETY PRECAUTIONS
G Do not attempt to install this air conditioner by yourself.
DANGER!
G This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
G When moving, consult authorized service personnel for disconnection and installa-
tion of the unit.
G Do not become excessively chilled by staying for lengthy periods in the direct cooling
airflow.
G Do not insert fingers or objects into the outlet port or intake grilles.
G Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
G Take care not to damage the power supply cord.
G In the event of a malfunction (burning smell, etc.), immediately stop operation, dis-
connect the power supply plug, and consult authorized service personnel.
G If the power supply cord of this appliance is damaged, it should only be replaced by
the authorized service personal, since special purpose tools and specified cord are
required.
G Provide occasional ventilation during use.
CAUTION!
G Do not direct air flow at fireplaces or heating apparatus.
G Do not climb on, or place objects on, the air conditioner.
G Do not hang objects from the indoor unit.
G Do not set flower vases or water containers on top of air conditioners.
G Do not expose the air conditioner directly to water.
G Do not operate the air conditioner with wet hands.
G Do not pull power supply cord.
G Turn off power source when not using the unit for extended periods.
G Check the condition of the installation stand for damage.
G Do not place animals or plants in the direct path of the air flow.
G Do not drink the water drained from the air conditioner.
G Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
G Do not apply any heavy pressure to radiator fins.
G Operate only with air filters installed.
G Do not block or cover the intake grille and outlet port.
G Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
G Avoid installing the air conditioner near a fireplace or other heating apparatus.
G When installing the indoor and outdoor unit, take precautions to prevent access to
infants.
G Do not use inflammable gases near the air conditioner.
En-1
2006.2.6, 1:17 PM
TYPE
COOLING MODEL
TYPE
MODÈLE REFROIDISSANT
TIPO
MODELO DE REFRIGERACIÓN
INDOOR UNIT
MODEL
UNIDAD INTERIOR
MW18C3F
MODÈLE
UNITÉ INTÉRIEURE
MODELO
OUTDOOR UNIT
UNIDAD EXTERIOR
MR18C3F
UNITÉ EXTÉRIEURE
SPECIFICATIONS
POWER SUPPLY ................................................................................................................................................... 208/230 V~60 Hz
COOLING
CAPACITY .............................................................................................................................................................. 18,000 BTU/h
INPUT POWER ................................................................................................................................................................1.73 kW
CURRENT ............................................................................................................................................................................. 7.7 A
FICHE TECHNIQUE
ALIMENTATION .................................................................................................................................................... 208/230 V~60 Hz
REFROIDISSEMENT
PUISSANCE FRIGORIFIQUE ................................................................................................................................ 18.000 BTU/h
PUISSANCE ABSORBÉE ............................................................................................................................................... 1,73 kW
INTENSITÉ ........................................................................................................................................................................... 7,7 A
ESPECIFICACIONES
ALIMENTACIÓN ................................................................................................................................................... 208/230 V~60 Hz
REFRIGERACIÓN
CAPACIDAD ........................................................................................................................................................... 18.000 BTU/h
ENTRADA DE ALIMENTACIÓN ..................................................................................................................................... 1,73 kW
CORRIENTE .......................................................................................................................................................................... 7,7 A