AZURO BP-30WS-B Manual De Uso Y Mantenimiento página 13

Bomba térmica para el calentamiento del agua en las piscinas

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 72
Remote device or control key
Activity
Setting pool water
and
temperature
Heat pump
starting
Stop
Switching OFF
7.0
MAINTENANCE AND INSPECTION
7.1
MAINTENANCE
CAUTION: The equipment includes live electrical components. Its housing may be opened by an electrician of adequate
technical qualification. There is a risk of electrical accident!
IMPORTANT: Before any attempt to make intervention into the equipment make sure it is fully disconnected from
its power supply.
(a) Clean regularly both the pool and the filtration unit to protect the equipment from damage due to fouled or clogged filter.
(b) Inspect regularly the power supply system, the condition of the supply cable in particular. In case the equipment begins to show operational irregularities,
switch it off immediately and contact an authorised service centre.
(c) Check regularly the working area of heat pump (see the figure in chapter 4.1 Site Selection) and keep it clean, free of debris, dead leaves or snow.
(d) If the heat pump is not used, disconnect it from the mains, drain it and cover it with an impermeable tarpaulin or PE foil.
(e) Wash the heat pump exterior with clean water and an ordinary kitchenware cleaning agent.
(f) Using a soft brush clean regularly the outer surfaces of evaporator and keep it free of any stuck dirt. The lamellae can be carefully cleaned using a flat, not
sharp tool. The guarantee shall not apply to any mechanical damage to the lamellae.
(g) Check regularly the tightness of screws (bolts) anchoring the equipment to the support and the screws fixing the covers. Check the supply cable for
damage and wear. Clean any rusted parts with a wire brush and treat them with corrosion resistant coating.
(h) Regularly remove the top cover and clean the heat pump from dirt.
(i) Any repair shall be carried out by a duly qualified technician.
(j) Any maintenance work of the cooling system shall be carried out by a duly qualified technician.
of heat pump
Selectable within
the range of
15 °C to 45 °C
Press the key
Press the key
Pull out the supply cable
plug from the mains socket
or switch OFF the circuit
breaker of HP supply circuit
(in case of fixed con-nection.
Display
Heat pump response
The HP heats or cools
water until achieving its
required temperature
The HP will be put into
operation within the time
interval of 1 – 3 min in its
previously set operating
mode (heating or cooling).
The HP stops immediately
and stays in the standby
state.
The heat pump gets
completely switched OFF.
13